• No results found

power supply voltage harmonics

Effect of Dynamic Voltage Restorer in Compensating for Voltage Sag and Controlling Harmonics in a Power Distribution System using Fumman Industry as a Case Study

Effect of Dynamic Voltage Restorer in Compensating for Voltage Sag and Controlling Harmonics in a Power Distribution System using Fumman Industry as a Case Study

... of voltage sag mitigation equipment that are available nowadays such as Uninterrupted Power Supply (UPS), flywheel, and the flexible ac technology (FACTS) devices which have been widely used in ...

7

Mitigation of Disturbances on Load Side using UPQC in an AC Microgrid

Mitigation of Disturbances on Load Side using UPQC in an AC Microgrid

... several power quality issues especially towards distribution ...mitigate supply and load side disturbances in ...electric power quality using UPQC was given by Khadem ...for power quality ...

7

Distributed generation with high voltage 
		gain DC DC converter integrated DVR as uninterrupted power supply

Distributed generation with high voltage gain DC DC converter integrated DVR as uninterrupted power supply

... phase power electronic conversion topologies are highly utilized in various commercial/residential applications for processing the energy ...range power switching components in such a way their wave- shapes ...

9

MODELING OF DSTATCOM USING NON LINEAR LOAD

MODELING OF DSTATCOM USING NON LINEAR LOAD

... of harmonics and compensate reactive power in Power ...inverter supply low harmonics distortion, reduced number of switches, suppression of switching losses and take out the Total ...

9

Mitigation of Disturbances on Load Side using UPQC in an AC Microgrid

Mitigation of Disturbances on Load Side using UPQC in an AC Microgrid

... several power quality issues especially towards distribution ...mitigate supply and load side disturbances in ...electric power quality using UPQC was given by Khadem ...for power quality ...

7

Combination Of Shunt Connected Converters To Synchronize Voltage And Harmonic Current Suppression

Combination Of Shunt Connected Converters To Synchronize Voltage And Harmonic Current Suppression

... the supply voltage and the grid current harmonics, a compensation method using coordinated control of two parallel interfacing converters is proposed in this ...the supply voltage to ...

5

Harmonic analysis in non – linear loads of power system

Harmonic analysis in non – linear loads of power system

... ideal power system voltage and current waveforms are purely ...the supply voltage exceeds that stored on the reservoir ...for harmonics. Non- linear loads create harmonics by ...

5

An Overarching Evaluation of Unified Power Quality Conditioner(UPQC) For Refinement in Power Quality

An Overarching Evaluation of Unified Power Quality Conditioner(UPQC) For Refinement in Power Quality

... of voltage and current. The series APF is inserts a voltage, which is added at a point of common coupling (PCC) such that the load end the voltage remains unaffected by any voltage ...

8

Mitigation of Voltage Sags/Swells to Enhance Power Quality of Distribution System Using a Custom Power Device (DVR)

Mitigation of Voltage Sags/Swells to Enhance Power Quality of Distribution System Using a Custom Power Device (DVR)

... as voltage sags/swells, flicker, harmonics distortion, impulse transient and interruptions ...[1]. Voltage sags can occur at any instant of time, with amplitudes ranging from 10-90% and a duration ...

9

THE ENERGY EFFICIENT CONVERTER UNIT WITH FILTERING OF THE HARMONICS OF THE OUTPUT VOLTAGE TRACTION POWER SUPPLY SYSTEM OF DC WITH VOLTAGE OF 3 KV

THE ENERGY EFFICIENT CONVERTER UNIT WITH FILTERING OF THE HARMONICS OF THE OUTPUT VOLTAGE TRACTION POWER SUPPLY SYSTEM OF DC WITH VOLTAGE OF 3 KV

... В настоящей статье рассматриваются характеристики такой комбинированной системы и доказывается, что при её использовании размеры фильтрового дросселя как основного элемента пассивного Г-[r] ...

7

Harmonics Reduction in Power Supply using DPFC                       

Harmonics Reduction in Power Supply using DPFC                       

... Each single-phase converter has its own series control through the transmission line. The principle utilization of the series controller to keep up its own particular capacitor dc voltage and to create series ...

7

AN ENHANCEMENT OF POWER QUALITY USING INTELLIGENT UNIFIED POWER QUALITY CONDITIONER TO MITIGATE VOLTAGE SAG AND SWELL

AN ENHANCEMENT OF POWER QUALITY USING INTELLIGENT UNIFIED POWER QUALITY CONDITIONER TO MITIGATE VOLTAGE SAG AND SWELL

... Unified Power Quality Conditioner which offers customers high quality of power has become an increased concern of ...the power quality disturbances such as current harmonics and voltage ...

7

APPLICATION OF ANN LOGIC CONTROLLER FOR IMPROVEMENT OF POWER QUALITY USING UPQC

APPLICATION OF ANN LOGIC CONTROLLER FOR IMPROVEMENT OF POWER QUALITY USING UPQC

... Custom power devices like DVR, D-STATCOM, and UPQC can enhance power quality in the distribution ...the power quality problem at the load or at the distribution system, there is a choice to choose ...

5

Comparative Performance Evaluation of Different Compensating Current Generation Techniques for Shunt Active Power Filter

Comparative Performance Evaluation of Different Compensating Current Generation Techniques for Shunt Active Power Filter

... Simulink power system ...active power filter based on Instantaneous PQ ...in harmonics. The shunt APF supply the harmonics and reactive power demand of the load and supply ...

5

A NOVEL APPROACH TO GENERATE TEST CASES FOR COMPOSITION & SELECTION OF WEB 
SERVICES BASED ON MUTATION TESTING

A NOVEL APPROACH TO GENERATE TEST CASES FOR COMPOSITION & SELECTION OF WEB SERVICES BASED ON MUTATION TESTING

... of power electronic technologies, voltage source inverter (VSI) fed drives are widely employed in industries generate harmonics and interharmonics resulting in serious power line ...pollution. ...

7

SIMULATION AND COMPARISON OF SINGLE PHASE MULTI HIGH LEVEL INVERTER FOR DIFFERENT LOADS

SIMULATION AND COMPARISON OF SINGLE PHASE MULTI HIGH LEVEL INVERTER FOR DIFFERENT LOADS

... Load harmonics can cause the over heating of the magnetic cores of transformer and ...source harmonics are mainly generated by power supply with non-sinusoidal voltage ...Multilevel ...

7

Unified Power Quality Conditioner for voltage and current compensation

Unified Power Quality Conditioner for voltage and current compensation

... utilizes power electronic based power processing devices for getting higher efficiency, accurate controllability, faster response and compact ...these power electronics devices (SCR, MOSFET, BJT and ...

6

Simulation & Analysis of Unified Power Quality Conditioner (UPQC) for Power Quality Improvement Keyur V. Patel, Priyank R Bhavsar

Simulation & Analysis of Unified Power Quality Conditioner (UPQC) for Power Quality Improvement Keyur V. Patel, Priyank R Bhavsar

... The power quality at distribution systems are old but customer recognition of these problems increased ...in Power Standard at distribution level has been reported in this ...electric power quality ...

12

Enhancement of Quality in Power Systems With Active Power Filters

Enhancement of Quality in Power Systems With Active Power Filters

... for power quality control have become more attractive compared with passive ones due to their fast response, smaller size, and higher ...the power factor; Power Factor Corrector (PFC) and Active ...

10

Integration of Artificial Intelligence Control to the Unified Power Quality Conditioner

Integration of Artificial Intelligence Control to the Unified Power Quality Conditioner

... growing power demands. It is very necessary to utilize the available power efficiently with as much less issues as possible rather than focusing on the excessive generation to meet the ...active ...

13

Show all 10000 documents...