• No results found

series-compensated power system

An Accurate Power System Fault Classification and Location Algorithm for Series Compensated Line

An Accurate Power System Fault Classification and Location Algorithm for Series Compensated Line

... the series compensation effect and the reactance effect resulting from the remote end in ...feed. Series Capacitors (SC) and Metal Oxide Varistors (MOV) schemes are made equivalent for the fundamental ...

6

Power Flow Control in Power System using Thyristor Controlled Series Capacitor (TCSC)

Power Flow Control in Power System using Thyristor Controlled Series Capacitor (TCSC)

... The series of capacitors are installed in series with a transmission line, which means that all equipment must be installed on a fully insulated ...the power supply ...of power lines and ...

6

Fault Location in Series Compensated Transmission Lines

Fault Location in Series Compensated Transmission Lines

... variable series compensation which also provides dy- namic power flow control, dampens the inter-area oscillations, and suppresses sub-synchronous resonance (SSR) ...Consequentially, series ...

94

Capacity Enhancement and Voltage Stability Improvement of Power Transmission Line by Series Compensation

Capacity Enhancement and Voltage Stability Improvement of Power Transmission Line by Series Compensation

... of series-shunt ...improve power transmission capability of EWIs (East-West Interconnectors) (from Ghorasal to Ishurdi) of Bangladesh Power Transmission ...using series compensation on a ...

10

Comparison of the Performance of IPFC (series series) and UPFC (series shunt) FACTS Controller in Power System

Comparison of the Performance of IPFC (series series) and UPFC (series shunt) FACTS Controller in Power System

... uncompensated system model is simulated using MATLAB/SIMULINK software. Power flow is obtained without any ...the system. In order to keep the system stable we have to provide reactive ...

7

The use of PIC Microcontrollers for Fault Classification of a Series Compensated Transmission Line

The use of PIC Microcontrollers for Fault Classification of a Series Compensated Transmission Line

... embedded system in protective devices used for medical and industrial instrument or other costly instrument which need to be saved from dangerous ...three-phase power transmission line with series ...

6

Current Directional Protection of Series Compensated Line Using Intelligent Classifier

Current Directional Protection of Series Compensated Line Using Intelligent Classifier

... abnormal system condition, the cur- rent signal seen by relay have significant secondary tran- sient due to the automatic firing the air ...after series capacitor (F2 in power system ...

9

Identification of faults in series compensated transmission line by using wavelet transform

Identification of faults in series compensated transmission line by using wavelet transform

... low power quality and can cause serious problem ...of power disturbances are laborious since they are primarily based on visual inspection of ...the system operating conditions and make correct ...

6

An Accurate Offline Phasor Estimation Technique For Fault Location In Series Compensated Lines

An Accurate Offline Phasor Estimation Technique For Fault Location In Series Compensated Lines

... electric power supply, the necessity to transmit more power has become the need of the ...excess power can be transferred by building new infras- tructure (costly and time taking) or by using ...

90

Wavelet Entropy Based Algorithm for Fault Detection and Classification in FACTS Compensated Transmission Line

Wavelet Entropy Based Algorithm for Fault Detection and Classification in FACTS Compensated Transmission Line

... the power transfer capability of existing transmission lines instead of constructing new ...the power flow along the transmission lines to meet the needs of power ...alter power sys- tem ...

9

Design and Implementation of Integrated Impedance Based Relay For Series Compensated Transmission Line

Design and Implementation of Integrated Impedance Based Relay For Series Compensated Transmission Line

... ac power transmission over long lines was primarily limited by the series reactive impedance of the ...line. Series capacitive compensation was introduced decades ago to reduce a portion of the ...

13

Series Compensated Transmission Lines Defects Observation & Classification Based on Wavelet Transform

Series Compensated Transmission Lines Defects Observation & Classification Based on Wavelet Transform

... Transmission System (FACTS) devices has been a very challenging ...in series with transmission system. The series devices are compensating reactive ...and power flow. These devices are ...

5

Dynamic Performance of Distance Relayson Series Compensated Transmission Lines using RTDS

Dynamic Performance of Distance Relayson Series Compensated Transmission Lines using RTDS

... in power system networks to increase power transfer capacity, improve the system stability, reduce system losses, improve voltage regulation and for achieving flexible power flow ...

7

Modeling and Simulation of PV Fed UPQC System Using Multilevel DC-DC Converter

Modeling and Simulation of PV Fed UPQC System Using Multilevel DC-DC Converter

... proposed system is shown in ...the series and shunt compensation the power quality problems such as voltage sag, voltage swell, real and reactive power are ...

5

A Novel Scheme to Identify Faults Occurring During Power Swing for a Series-Compensated Line

A Novel Scheme to Identify Faults Occurring During Power Swing for a Series-Compensated Line

... a series-compensated line during power swing is ...of series compensated transmission line during usual operating condition and power swing condition due to certain reasons like ...

8

Grid Connected Solid Oxide Fuel Cell and Solar Photovoltic Hybrid Power Generating System

Grid Connected Solid Oxide Fuel Cell and Solar Photovoltic Hybrid Power Generating System

... supply, series active power filter, a nonlinear load and a series ...star system allows us to use two different ...220/440-volt system, it provides 220V between the neutral and one of ...

8

The Effect of Different Representations of Wind Turbines on the SSR Analysis in the Double Cage Induction Generator Based Wind Farm

The Effect of Different Representations of Wind Turbines on the SSR Analysis in the Double Cage Induction Generator Based Wind Farm

... a series-compensated line is studied and their effect on the Subsynchronous Resonance (SSR) is ...test system eigenvalues are obtained for different conditions of the power system and ...

12

Standards-based wireless sensor networks for power system condition monitoring

Standards-based wireless sensor networks for power system condition monitoring

... Security is paramount in any industrial system to mitigate against intrusions and to maintain data confidentiality and integrity. Security presents an additional challenge in WSNs as the network uses a wireless ...

20

Comparison of SVC and TCSC for Transient Stability Enhancement of Multi-machine System

Comparison of SVC and TCSC for Transient Stability Enhancement of Multi-machine System

... test system considered for transient stability investigation is standard IEEE 3 machine 9 buses ...test system is operating with load at bus 5 carrying 125 MW, bus 6 carrying 90 MW and bus 8 carrying 100 ...

10

Harmonic Identification and Mitigation using APF in Distribution System Consisting of Single Non Linear Load

Harmonic Identification and Mitigation using APF in Distribution System Consisting of Single Non Linear Load

... active power filter configurations but hysteresis method is preferred among other current control methods because of quick current controllability, easy implementation and unconditioned stability ...

7

Show all 10000 documents...