• No results found

zero-current switching turn-off

Design and Analysis of a New Soft-Switching Multi-Output Fly-Back Converter

Design and Analysis of a New Soft-Switching Multi-Output Fly-Back Converter

... at zero voltage- switching turn-on and zero-current-switching turn-off condition are achieved to gate control without additional ...at zero-current- ...

8

Comparative Study of ZCT-ZVT PWM Boost Converter and Interleaved Boost Converter

Comparative Study of ZCT-ZVT PWM Boost Converter and Interleaved Boost Converter

... with Zero Voltage Transition (ZVT), Zero Current Transition (ZCT) and Pulse Width Modulation (PWM) ...input current and output ...to turn on with zero-voltage transition (ZVT) ...

9

Design of zero current switching DC DC buck converter

Design of zero current switching DC DC buck converter

... the current transient which forced to zero before the power device is ...to turn off without current flowing through ...the current and voltage overlap is overcome by ensuring ...

38

Design Topology of Low Profile Transformer forSlim Adaptor

Design Topology of Low Profile Transformer forSlim Adaptor

... external resonant inductor. [8] ZVS capability from the zero load to the full load and low turn-off current for primary side switches, so switching loss is ...

9

A Multi Input Multi Output Converter for Hybrid Energy Systems

A Multi Input Multi Output Converter for Hybrid Energy Systems

... acieve zero current switching during turn-off and zero voltage switching during turn-on to alleviate the switching ...

8

Soft switching current fed 
		push pull converter for PV application

Soft switching current fed push pull converter for PV application

... soft switching single-inductor push-pull converter is ...the zero voltage switching condition and turned off at zero current switching condition through parallel resonance ...

6

A Novel Soft Switching Pwm DC DC Converter

A Novel Soft Switching Pwm DC DC Converter

... device switching at high frequency is a major contributor to power loss in ...converters. Switching devices absorb power when they turn on or off if they go through a transition when both ...

8

Interleaved Current-Fed Resonant Converter with High Current Side Filter For EV And HEV Applications

Interleaved Current-Fed Resonant Converter with High Current Side Filter For EV And HEV Applications

... the turn-off losses of switches and diodes resonant converterswith ZVS or zero current switching (ZCS)capabilities, such as SRC and LLC could be considered as candidates for the ...The ...

7

Digital Simulation of Asymmetrical PWM Full-Bridge Converter using Simulink

Digital Simulation of Asymmetrical PWM Full-Bridge Converter using Simulink

... soft switching, which means Zero Voltage Switching (ZVS) and Zero Current Switching (ZCS) ...ZVS turn-on of power switches of primary side and to minimize circulating ...

9

A New ZVZCS Isolated Dual Series Resonant DC-DC Converter with EMC Considerations

A New ZVZCS Isolated Dual Series Resonant DC-DC Converter with EMC Considerations

... phase-shifted zero-voltage switching full-bridge converter is one of the most attractive techniques, as it allows all switches to operate at zero-voltage turn-on switching (ZVS) by ...

9

Theoretical analysis of Zero Voltage and Zero Current Switching Resonant Pulse Width Modulation for High Power Applications

Theoretical analysis of Zero Voltage and Zero Current Switching Resonant Pulse Width Modulation for High Power Applications

... soft switching, zero voltage switches are turn on in continuous conduction mode (CCM) causes low stress across the switches and zero current switched off the diodes which leads ...

5

A Low Power Single stage LED Driver Operating between Discontinuous Conduction Mode and Critical Conduction Mode

A Low Power Single stage LED Driver Operating between Discontinuous Conduction Mode and Critical Conduction Mode

... a turn-on switching process is initiated when the output diode current falls to zero, while a turn-off switching process is established when the peak transistor ...

10

A HIGH EFFICIENCY RESONANT CONVERTER FOR WIND POWER GENERATION UNDER RAPIDLY CHANGING ENVIRONMENTAL CONDITIONS

A HIGH EFFICIENCY RESONANT CONVERTER FOR WIND POWER GENERATION UNDER RAPIDLY CHANGING ENVIRONMENTAL CONDITIONS

... high switching frequency is needed to accomplish little ...the switching losses are directly related with the switching frequency ,therefore decreasing efficiency of the resonant ...smooth ...

8

A Transformerless Soft Switching Resonant PWM (RPWM) Boost Converter for High Step up Applications

A Transformerless Soft Switching Resonant PWM (RPWM) Boost Converter for High Step up Applications

... of current reverse recovery characteristics of output diodes are greatly ...controlling current changing rates of diode with use of coupled inductor reverse recovery problems are removed and also without ...

6

Design and Development of DC-DC Resonant Converter for DC Power Systems

Design and Development of DC-DC Resonant Converter for DC Power Systems

... Imperfect switching is a major contributor to power loss in converters. Switching devices absorb power when they turn on or off if they go through a transition when both voltage and ...

9

A Hybrid Resonant ZCS PWM Converter for Photovoltaic Energy Sources Using Bat Algorithm

A Hybrid Resonant ZCS PWM Converter for Photovoltaic Energy Sources Using Bat Algorithm

... of zero-current-switching (ZCS) for main switches are presented in this ...large turn-off current of main switches of the conventional zero-voltage and ...

5

An Improved Active-Clamped DC-DC Converter with Modified PI Controller

An Improved Active-Clamped DC-DC Converter with Modified PI Controller

... provides zero-current turn-off ...the current stress of the current-fed side switches are limited by auxiliary dual active-clamping circuits on both sides, and ...

8

An Overview of Boost Converter Topologies With Passive Snubber

An Overview of Boost Converter Topologies With Passive Snubber

... A comparison of 2 different soft switched topologies with passive snubber circuit is shown in Table II. Simulation is performed by MATLAB/SIMULINK using the same parameters. The result shows that converter of [2] has ...

7

Magnetic Saturation Impacts on Fault Analysis of Squirrel-Cage Induction Motors using Winding Function Approach

Magnetic Saturation Impacts on Fault Analysis of Squirrel-Cage Induction Motors using Winding Function Approach

... Two different test rigs were used to provide the experimental results. The first one consists of an 11kW, 380V, 50Hz, 4-poles, the Δ-connected SCIM (SCIM I) mechanically coupled with a DC generator, while a variable ...

11

Survey Paper of Performance Analysis of Class EF2 Inverter and Rectifier for Wireless Power Transfer Systems

Survey Paper of Performance Analysis of Class EF2 Inverter and Rectifier for Wireless Power Transfer Systems

... the switching frequency, in parallel with the switch, referred to as class ...load current does not contain a second-harmonic component, and therefore, has an improved EMI performance, whereas the Class-E ...

10

Show all 10000 documents...