• No results found

[PDF] Top 20 Cable vibration caused by wind

Has 10000 "Cable vibration caused by wind" found on our website. Below are the top 20 most common "Cable vibration caused by wind".

Cable vibration caused by wind

Cable vibration caused by wind

... motion caused by the variability of forces that affects cables which are in the wake of other structural elements ...high wind velocities and is associated with high vibration ...critical wind ... See full document

6

Progressive Collapse of Cable Stayed Bridge under Blast Loading

Progressive Collapse of Cable Stayed Bridge under Blast Loading

... different. Cable stayed bridges are less expensive quicker to build and has grater ...event caused by localized structural injuries, disturbing the initial load equilibrium causes vibrations in the ... See full document

9

Adaptive Vibration Control for Cable-Bridge Coupled Uncertain Nonlinear System

Adaptive Vibration Control for Cable-Bridge Coupled Uncertain Nonlinear System

... Considering wind, railway, and highway loadings in paper [3], dynamic stress analysis of long suspension bridges is ...about vibration response, monitor and analysis [9-12], vibration control for ... See full document

8

Optimization of offshore wind farm power cable routing : development of a tool that optimizes the power cable route design for offshore wind farms

Optimization of offshore wind farm power cable routing : development of a tool that optimizes the power cable route design for offshore wind farms

... Results presented in table 4.8 show that for a fixed burial depth of 1.0, the horizontal optimization reduces the total costs. For a burial depth of 1.5 and 2.0 meter however, the total horizontal optimization costs are ... See full document

94

Comparison of Natural Frequency Vibration Analysis for a Bridge Using Accelerometers and a Piezoelectric Cable Vibration Sensor

Comparison of Natural Frequency Vibration Analysis for a Bridge Using Accelerometers and a Piezoelectric Cable Vibration Sensor

... piezoelectric cable along the entire length of a reinforced concrete slab to sense crack generation occurring within ...methods caused by generation of a tiny signal corresponding to very small ... See full document

9

Experimental Study on Bridge Stay Cable Vibration Mitigation Using External Viscous Damper

Experimental Study on Bridge Stay Cable Vibration Mitigation Using External Viscous Damper

... of cable cross-section. Many researchers conducted wind tunnel tests or numerical simulation to justify the effectiveness of aerodynamic control ...1998): Cable surface indentations (Figure 2-6) and ... See full document

140

Prediction of Wind Loads on Tall Buildings: Development and Applications of an Aerodynamic Database

Prediction of Wind Loads on Tall Buildings: Development and Applications of an Aerodynamic Database

... random vibration theory, and implemented in WAD to calculate the peak base bending moments about the x- and y-axes and peak base torque of the building corresponding to arbitrary wind attack ...static ... See full document

128

Noise and vibration from building mounted micro wind turbines
Part 2: Results of measurements and analysis

Noise and vibration from building mounted micro wind turbines Part 2: Results of measurements and analysis

... in wind speed and as such there is a lag, sometimes greater than 4 seconds, between the rotational speed and the wind speed; this is especially true for periods where the rate of change of wind speed ... See full document

129

Study on vibration attenuation and load reduction of wind turbines based on
tuned mass damper

Study on vibration attenuation and load reduction of wind turbines based on tuned mass damper

... interference caused by exceptional cases, we chose the variation range of damping ratio ζ between ...the vibration inhibition effect of the tower top made by the change of damping ratio has been ... See full document

12

A new energy-based method for evaluating the damping properties of cable-damper systems.

A new energy-based method for evaluating the damping properties of cable-damper systems.

... stay cable is sensitive to dynamic excitation. Wind is an important source of external excitation which can cause cable ...vibration. Wind-induced cable vibration can be ... See full document

92

Numerical investigation of the coupled interaction between an unsteady aerodynamic flow field and a water film coating on a circular cylinder

Numerical investigation of the coupled interaction between an unsteady aerodynamic flow field and a water film coating on a circular cylinder

... 6 and Ruscheweyh 1998; Gu and Du 2005; Wang et al. 2005). Both classes indicate that it is the presence of the rivulet on the upper surface which is largely responsible for the vibration (Matsumoto et al. 1995), ... See full document

47

The effectiveness of vibration damper attached to the cable due to wind action

The effectiveness of vibration damper attached to the cable due to wind action

... of vibration of cable with attached damper is ...the cable is characterized by mass, stiffness and damping ...the cable with damper, taking into account the initial parameters: cable ... See full document

5

Impact of Cable-deck Interaction on the Efficiency of External Damper in Controlling Stay Cable Vibration on Cable-Stayed Bridges

Impact of Cable-deck Interaction on the Efficiency of External Damper in Controlling Stay Cable Vibration on Cable-Stayed Bridges

... the cable is horizontal and the vibration excited by the deck vertical motion becomes a forced vibration whereas when the angle of inclination is 90 , , the cable is vertical and deck motion ... See full document

125

Research Status and Development Direction of Piezoelectric Wind Energy Harvesting Technology

Research Status and Development Direction of Piezoelectric Wind Energy Harvesting Technology

... Traditional wind power generation was caused by the relative movement between the rotor and ...of wind-induced vibration of piezoelectric energy harve- ster was the use of wind-induced ... See full document

10

A STUDY ON VIBRATION CONTROLLER AND SEISMIC RESISTANT CABLE STAYED BRIDGE WITH MODEL

A STUDY ON VIBRATION CONTROLLER AND SEISMIC RESISTANT CABLE STAYED BRIDGE WITH MODEL

... The impact of earthquake on human life and structure like bridge, multistorey building, liquid storing container, bunker etc . is very poor which was seen in last few years. The main aim of this work to protect ... See full document

6

The Design of the Site Dynamic Balance Test System Based on ARM

The Design of the Site Dynamic Balance Test System Based on ARM

... the vibration signal caused by the unbalance of the ...The vibration signal is changed into electrical signals (such as voltage and current), which can be measured by the sensor, and then through a ... See full document

8

Study on Unbalanced Magnetic Pulling Analysis and Its Control Method for Primary Helium Circulator of High-Temperature Gas-Cooled Reactor

Study on Unbalanced Magnetic Pulling Analysis and Its Control Method for Primary Helium Circulator of High-Temperature Gas-Cooled Reactor

... for vibration control. Besides synchronous vibration produced by mass imbalance and sensor runout, double-frequency vibration produced by unbalanced magnetic pull (UMP) is serious in PHC engineering ... See full document

17

Review of Vibration Signal Processing Techniques Towards Gear Pairs Damage Identification

Review of Vibration Signal Processing Techniques Towards Gear Pairs Damage Identification

... them vibration signal processing technique is well ...the vibration signals measured from gearboxes are non- stationary and transient in nature, when damage occurs it is even more interesting to carry out ... See full document

5

Offshore wind farm electrical cable layout optimization

Offshore wind farm electrical cable layout optimization

... The overall programme approach is outlined below: Algorithm 1 Offshore Wind Farm Inter-Array Cable Optimization Require: The turbine positions, the GIS obstacles, and the number of subst[r] ... See full document

22

Study on Moving Bodies Identification Algorithm Based on Piezoelectric Cable Vibration Signals

Study on Moving Bodies Identification Algorithm Based on Piezoelectric Cable Vibration Signals

... after it passed. Besides, the produced vibration signals increase in crawler belts’ progressing, so there are more peak points in final signal images. Set characteristic quantity pv to represent peak value. As is ... See full document

8

Show all 10000 documents...