Active Power Filter Control Using Adaptive Signal  Processing Techniques

Active Power Filter Control Using Adaptive Signal Processing Techniques

... Computation of the load harmonic compensation current is performed by the adaptive notch infinite impulse response IIR filter.. Performance of the proposed scheme has been verified by co[r] ...

5

Analysis of Shunt Active Filter with ANN based Controller

Analysis of Shunt Active Filter with ANN based Controller

... of Active power filter has been developed so ...shunt active power filter is a method of removing harmonics by supplying the harmonic current to the load in opposite direction to ...

6

Control of Shunt Active Power Filter for Improvement of Power Quality

Control of Shunt Active Power Filter for Improvement of Power Quality

... of Power supplied is affected by various factors of the power ...the Power Quality problems are introduce in to the system by the Power Electronics equipment because of its fast switching and ...

8

CONTROL OF SHUNT ACTIVE POWER FILTER IN A POWER SYSTEM USING MATLAB/SIMULINK

CONTROL OF SHUNT ACTIVE POWER FILTER IN A POWER SYSTEM USING MATLAB/SIMULINK

... Two control techniques for a three-phase shunt active power filter employing a conventional three-leg converter were developed and a critical comparison between both approaches was carried ...

12

Active Power Filter for Renewable Energy applications Using Predictive Control Scheme

Active Power Filter for Renewable Energy applications Using Predictive Control Scheme

... an active power filter implemented with a four-leg voltage-source inverter using a predictive control scheme is ...the active power filter, including the effect of the ...

6

Application of Active Power Filters to compensate reactive power

Application of Active Power Filters to compensate reactive power

... ABSTRACT: Active power filters (APFs) play an important role in elimination of power system ...reactive power. In this paper, reactive power compensation along with removing of network ...

7

Integration of Artificial Intelligence Control to the Unified Power Quality Conditioner

Integration of Artificial Intelligence Control to the Unified Power Quality Conditioner

... series active power filter and shunt active power ...series active power filter is harmonic isolation between a sub-transmission system and a distribution system; ...

13

Vol 3, No 10 (2015)

Vol 3, No 10 (2015)

... One of the major advantages of the dq-based current reference generator scheme is that it allows the implementation of a linear controller in the dc- voltage control loop. However, one important disadvantage of ...

7

SEVEN LEVEL CONTROL OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENHANCEMENT

SEVEN LEVEL CONTROL OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENHANCEMENT

... current to inject the desired compensation current into the line. There are two major approaches that have emerged for the harmonic detection, namely, time domain and the frequency domain methods. The frequency domain ...

10

Efficient Control of Shunt Active Power Filter with Self- Adaptive Filter Using Average Power Algorithm

Efficient Control of Shunt Active Power Filter with Self- Adaptive Filter Using Average Power Algorithm

... by power electronic equipment has become important because of its growing use in industrial ...Filters, Active Power Filters (APFs) and Hybrid Active Power Filters ...

6

Fuzzy Logic Based UPQC by Addition of a Superconducting Magnetic Energy Storage System

Fuzzy Logic Based UPQC by Addition of a Superconducting Magnetic Energy Storage System

... any power quality problem occurs in one feeder, other adjacent feeder supplies power for compensating power quality ...Unified Power Quality Conditioner (UPQC) consists of two IGBT based ...

6

Control Strategy of Three Phase Shunt Active Power Filter for Power Quality Improvement

Control Strategy of Three Phase Shunt Active Power Filter for Power Quality Improvement

... The Synchronous Detection Algorithm relies in the fact that the three phase currents are balanced. The average power is calculated and divided equally between the three phases. The signal is then synchronized ...

6

An active noise control algorithm with gain and power constraints on the adaptive filter

An active noise control algorithm with gain and power constraints on the adaptive filter

... output power constraint of 25% of the un- constrained value (−6 ...6-dB power reduction over ...the power constraint to be set explicitly, while the leaky LMS requires a trial and error approach to ...

12

Improvement of Power Quality by using Control Strategy of Series Active Filter

Improvement of Power Quality by using Control Strategy of Series Active Filter

... to power quality problems are presented by active power ...available active power filters are: shunt active filter, series active filter and hybrid ...

5

Comparative of Conventional and Intelligence Controller based Hybrid Generation Scheme Fed Active Filter Compensation Scheme for Power Quality Features

Comparative of Conventional and Intelligence Controller based Hybrid Generation Scheme Fed Active Filter Compensation Scheme for Power Quality Features

... high power density, low voltage fluctuations, improve the grid stability, may increase the ...predictive control for the converter current loop proved to be an effective solution for active ...

13

Performance Analysis of A PI Controller and A Fuzzy Controller for Single Phase Shunt Active Power Filter

Performance Analysis of A PI Controller and A Fuzzy Controller for Single Phase Shunt Active Power Filter

... APF control circuit is generating appropriate gating signals for the power switches that forces the filter current follow derived reference ...current control method is used because ...

8

Reduction of Harmonics by using Control of SVPWM for Shunt Active Filter with 3-Phase, 3-Wire Distribution system

Reduction of Harmonics by using Control of SVPWM for Shunt Active Filter with 3-Phase, 3-Wire Distribution system

... shunt active power filter as a reliable and cost-effective solution to power quality ...the active filter is installed at a distorted and unbalanced distribution network, the ...

7

Elimination of harmonics in power system by the combination of passive and active filter with p q control technique

Elimination of harmonics in power system by the combination of passive and active filter with p q control technique

... of active have been e basis of a combination of active filter and passive elements such as capacitors and reactors (Majid Pakdel 2007; Akagi et ...series active filter and shunt passive ...

6

Predictive Controller based Active Power Filter for Power Quality Control

Predictive Controller based Active Power Filter for Power Quality Control

... predictive control algorithm designed and implemented specifically for this ...Traditionally, active power filters have been controlled using pre-tuned controllers, such as PI-type or adaptive, for ...

5

Control Strategies for a Shunt Active Power Filter to Improve Power Quality

Control Strategies for a Shunt Active Power Filter to Improve Power Quality

... the control rule set; a decision-making logic which, simulating a human decision process, infer the fuzzy control action from the knowledge of the control rules and linguistic variable definitions; a ...

7

Show all 10000 documents...