• No results found

current-source active filter

Compensation of current harmonic components using an active power filter with four leg voltage source inverter
Rajasekhar Mudadla & B Venkata Ramana

Compensation of current harmonic components using an active power filter with four leg voltage source inverter Rajasekhar Mudadla & B Venkata Ramana

... The four-leg PWM converter topology is shown in Figure 1 the converter topology is similar to the conventional three-phase converter with the fourth leg connected to the neutral wire of the system. The four- leg ...

6

Improved Active Power Filter Performance by Instantaneous Power Theory

Improved Active Power Filter Performance by Instantaneous Power Theory

... voltage source converter to act as a four leg Active Power Filter (APF) using of instantaneous power theory is ...voltage- source inverter allows the compensation of current harmonic ...

5

Synchronous Reference Frame Based Hybrid Shunt Filter for Current Harmonic Compensation

Synchronous Reference Frame Based Hybrid Shunt Filter for Current Harmonic Compensation

... hybrid filter The main circuit of the active filter is the VSI with PWM modulation using IGBT switches The current source hybrid power filter is a combination of current ...

5

Performance improving of active power filter in microgrid system by using fuzzy controller

Performance improving of active power filter in microgrid system by using fuzzy controller

... an Active Power Filter implemented with a four leg voltage source inverter using dq (synchronous reference frame) based current reference generator scheme is ...voltage source inverter ...

7

Source Current Harmonics Reduction with Intelligent controlled Multiple RES based SAPF

Source Current Harmonics Reduction with Intelligent controlled Multiple RES based SAPF

... incorporating active power filter ...compensate current unbalance, load current harmonics, load reactive power demand and load neutral ...

7

Elimination of Harmonics to Enhance the Power Quality by using SAPF

Elimination of Harmonics to Enhance the Power Quality by using SAPF

... and current which are not good for the equipment’s at ...Shunt active power filters compensates load by injecting equal but opposite harmonic compensating ...shunt active power filter operates ...

8

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

... 1) current and voltage measurement circuits, 2) reference current generation circuit PWM ...load current, il is measured indirectly as the difference between supply current, is and the APF ...

5

Reduction of Harmonic exploitation 
		DSP controller based shunt active 
		filter for PEMFC fed non linear load

Reduction of Harmonic exploitation DSP controller based shunt active filter for PEMFC fed non linear load

... voltage source (sinusoidal) supplying energy to nonlinear load and a current controlled three-phase active power filter associated in parallel with the nonlinear ...The filter comprises ...

6

Control Implementations for High Bandwidth Shunt Active Filter.

Control Implementations for High Bandwidth Shunt Active Filter.

... Passive filter consists of a Series/Parallel combination of an inductor, a capacitor and a resistor specially tuned to filter a particular frequency ...tuned filter is lower than the source ...

91

Elimination of Harmonics Using Active Power Filter Based on DQ Reference Frame Theory

Elimination of Harmonics Using Active Power Filter Based on DQ Reference Frame Theory

... Abstract-— Active power filters have the following multiple functions; harmonic filtering, damping, isolation and termination, reactive-power control for power factor correction and voltage regulation, load ...

5

THREE-PHASE ACTIVE POWER FILTER CONTROLLER FOR BALANCED AND UNBALANCED NON-LINEAR LOAD

THREE-PHASE ACTIVE POWER FILTER CONTROLLER FOR BALANCED AND UNBALANCED NON-LINEAR LOAD

... The active power filter produces equal but opposite harmonic currents to the point of connection with the nonlinear ...based current controlled voltage source inverter with a dc bus capacitor ...

11

International Transaction of Electrical and Computer Engineers System

International Transaction of Electrical and Computer Engineers System

... The active clamp technique is also used in some circuits ...the active filter not only would not cause the harmonic decrease of current source, but will decrease the voltage stress ...

11

Power Quality Improvement by Using Fuzzy Controlled Four Leg Inverter for Renewable Energy Sources

Power Quality Improvement by Using Fuzzy Controlled Four Leg Inverter for Renewable Energy Sources

... Generally, current controlled voltage source inverters are used to interface the intermittent RES in distributed ...as active inductor at a certain frequency to absorb the harmonic ...shunt ...

7

Fuzzy Controlled Shunt Hybrid Power Filter and Thyristor-Controlled Reactor for Power Quality

Fuzzy Controlled Shunt Hybrid Power Filter and Thyristor-Controlled Reactor for Power Quality

... Hybrid Active Filter (SHAF) with nonlinear load to minimize the source current harmonics and provide reactive power ...Hybrid Active Filter is constituted by Active ...

9

Improvement of Power Quality Using Fuzzy Based

Improvement of Power Quality Using Fuzzy Based

... most active and fruitful areas for research in the applications of fuzzy set theory, especially in the realm of industrial process, which do not lend of quantities data regarding the input-output ...Shunt ...

9

Unified Power Quality Conditioner for Power Quality Improvement with Induction Motor Drive

Unified Power Quality Conditioner for Power Quality Improvement with Induction Motor Drive

... shunt active filter is always maintaining the unity power ...sag source current will be zero. So that the active power requirement will be more in this ...additional active power ...

7

SYMMETRIC CRYPTOGRAPHY KEYS MANAGEMENT FOR 6LOWPAN NETWORKS

SYMMETRIC CRYPTOGRAPHY KEYS MANAGEMENT FOR 6LOWPAN NETWORKS

... renewable source to the grid and as shunt active power filter to compensate load current harmonics, load reactive power demand, and current ...reference current needs to be ...

7

Design of STATCOM for Power System Stability Improvement

Design of STATCOM for Power System Stability Improvement

... the active power filter is implemented with a four quadrant current Controlled PWN converter in between Source and load ...This current controlled converter does not sense the ...

9

An Efficient Particle Swarm Optimization Technique for 4 Leg Shunt Active Power Filter

An Efficient Particle Swarm Optimization Technique for 4 Leg Shunt Active Power Filter

... Abstract This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbala[r] ...

14

THD reduction using Shunt Active Filter

THD reduction using Shunt Active Filter

... shunt active filter connected to a simple power system is shown in ...voltage source (Va, Vb , Vc) feeding a three phase diode bridge rectifier with resistive ...a current controlled voltage ...

7

Show all 10000 documents...

Related subjects