• No results found

Fluorescence detector

Detection of Phytomelatonin in Medicinal 
										Plant Huang-qin Using High Performance 
										Liquid Chromatography-Fluorescence 
										Detector

Detection of Phytomelatonin in Medicinal Plant Huang-qin Using High Performance Liquid Chromatography-Fluorescence Detector

... A HPLC-FD HP 1100 series (Agilent technologies; Foster City, CA, USA) was employed to detect melatonin extracts from the samples of plant tissue. The HPLC system consisted of a reverse-phase column C18 110A (250 × 4.60 ...

6

Short Time Derivatization Method for Analysis of Abamectin in Water Using High Performance Liquid Chromatography Coupled to Fluorescence Detector

Short Time Derivatization Method for Analysis of Abamectin in Water Using High Performance Liquid Chromatography Coupled to Fluorescence Detector

... a fluorescence detector (HPLC-FLD, Agilent Tech- nologies ® 1200 series, Waldbronn, Germany) was used to analyze abamectin, with a Partisil 5 ODS-3 column (250 × ...

8

A next-generation ground array for the detection of ultrahigh-energy cosmic rays: the Fluorescence detector Array of Single-pixel Telescopes (FAST)

A next-generation ground array for the detection of ultrahigh-energy cosmic rays: the Fluorescence detector Array of Single-pixel Telescopes (FAST)

... in azimuth. The telescope frames were assembled on site, before the PMTs were mounted in the camera box and the UV band-pass filter was installed at the telescope aperture. The telescopes were aligned astrometrically ...

6

Simulation of the optical performance of the Fluorescence detector Array of Single-pixel Telescopes

Simulation of the optical performance of the Fluorescence detector Array of Single-pixel Telescopes

... by fluorescence detection of UHECRs with a giant ground ...based fluorescence detector (FD) telescope concept which would fulfil these ...The Fluorescence detector Array of Single-pixel ...

6

Determination of T-2 Mycotoxin in Fusarium strains by HPLC with fluorescence detector

Determination of T-2 Mycotoxin in Fusarium strains by HPLC with fluorescence detector

... In this study, HPLC-F detection of T-2 toxin from Fusarium strains is studied.. Materials and Methods.[r] ...

6

Development of the calibration device using UAV mounted UV-LED light source for the fluorescence detector

Development of the calibration device using UAV mounted UV-LED light source for the fluorescence detector

... Abstract. We have developed a standard UV-LED light source mounted on an unmanned aerial vehicle (UAV), so-called the Opt-copter, for the calibration of the fluorescence detectors (FDs) of the Telescope Array ...

5

Average shape of longitudinal shower profiles measured at the Pierre Auger Observatory

Average shape of longitudinal shower profiles measured at the Pierre Auger Observatory

... The Fluorescence Detector (FD) of the Pierre Auger Ob- servatory [1] has collected unprecedented statistics of high quality data, imaging the longitudinal profile of the elec- tromagnetic component of ...

5

Mass sensitive observables of the Pierre Auger Observatory

Mass sensitive observables of the Pierre Auger Observatory

... surface detector (SD) and a fluorescence detector ...27 fluorescence telescopes [4] which observe the longitudinal air shower development during clear new- to half-moon nights with a duty ...

6

Fluorescent Voltage Imaging Technique for the Measurement of Molluscan Neural Activities

Fluorescent Voltage Imaging Technique for the Measurement of Molluscan Neural Activities

... The electrophysiological methods using microelectrodes are not appropriate for the simultaneous measurement of neu- ral activities of many neurons. To overcome the difficulty, the fluorescent imaging technique using ...

5

1090.pdf

1090.pdf

... chloride and acetonitrile as constituents of the mobile phase. The selected method consisted of an HPLC separation on a reversed phase column (Supelcosil LC-PAH (5 micron)) using a mixture of methanol/water (80/20) as ...

181

FLUORESCENCE QUENCHING AS AN INDICATOR OF THE CONFORMATIONAL CHANGE OF HUMIC ACIDS

FLUORESCENCE QUENCHING AS AN INDICATOR OF THE CONFORMATIONAL CHANGE OF HUMIC ACIDS

... on fluorescence detector, although neither molecular size change nor significant absorbance increase was observed on UV-VIS ...general fluorescence increase indicating humic acid ...

8

The KamLAND Outer Detector

The KamLAND Outer Detector

... Inner Detector. However, because the Outer Detector is not spherically shaped, the distance to the starting points from the center of the Inner Detector varies between 987 and 1393 cm, as shown in ...

147

 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DETECTORS - A REVIEW

 HIGH PERFORMANCE LIQUID CHROMATOGRAPHY DETECTORS - A REVIEW

... This detector is based on three steps such as nebulisation, evaporation and detection. Eluent from HPLC column is transformed into a fine mist of droplets, using nebulizer. Small droplets are selected in order to ...

7

A New Adaptive Linear Combined CFAR Detector in Presence of Interfering Targets

A New Adaptive Linear Combined CFAR Detector in Presence of Interfering Targets

... proposed detector than the ...CA-CFAR detector, the computational load is reduced to only two additions and two subtractions whatever the reference window ...OS-CFAR detector, the computational load ...

21

Validation of Autonomous Microbe Sensor Prototype for Monitoring of Microorganisms in Injection Seawater Systems

Validation of Autonomous Microbe Sensor Prototype for Monitoring of Microorganisms in Injection Seawater Systems

... The fluorescence signal is triggered when the SYBR Green binds to ...the fluorescence sig- nal was measured (Figure 3). The detected fluorescence signal illustrated that the de- tection limit can be ...

21

Fluorescence Optofluidic Microscopy and Fluorescence Microscopy Based on the Talbot Effect

Fluorescence Optofluidic Microscopy and Fluorescence Microscopy Based on the Talbot Effect

... detected fluorescence associated with each focused spot by the CMOS sensor without ...The fluorescence from a fluorophore in the center of one of the focused light spots would spread over an area of ...

122

ALCOHOL DETECTOR

ALCOHOL DETECTOR

... We here propose an alcohol sensing system that measures alcohol intake, displays percentage of.. Our system first uses the alcohol sensor in order to detect alcoh[r] ...

5

Network Detector

Network Detector

... called fluorescence, and has many practical ...observe fluorescence, since other types of ultraviolet lamps emit visible light which drowns out the dim fluorescent ...

9

The PADME Detector

The PADME Detector

... To have a more accurate beam monitor capability, in the target region will be installed a system based on two planes of silicon pixel detectors placed up and down stream the diamond target. Each plane will consist of two ...

5

Detectors  Fluorescence Detection pdf

Detectors Fluorescence Detection pdf

... uorescence detector affords greater sensitivity to sample concen- tration than other ...uorescent detector is in contrast to those detectors that involve light absorption measurements, where the signal is ...

7

Show all 6036 documents...