• No results found

hot-wire

High Sensitivity 'Hot-wire'-based Gas Velocity Sensor for safe monitoring in mining applications

High Sensitivity 'Hot-wire'-based Gas Velocity Sensor for safe monitoring in mining applications

... fiber-optical hot-wire sensor probe, based on the schematic design shown in Figure 2, were manufactured and evaluated, and designated Probes 1, 2 and ...

9

Response of the Nevzorov hot wire probe in clouds dominated by droplet conditions in the drizzle size range

Response of the Nevzorov hot wire probe in clouds dominated by droplet conditions in the drizzle size range

... begin quite early to curve around the sensor and thus don’t impact as efficient as on the smaller LWC sensor obstacle. Droplet sizes beyond several tens of micrometers, however, should impact more efficiently on the TWC ...

10

The influence of precursor gas pressure on structure and properties of fluoropolymer coatings by hot wire CVD

The influence of precursor gas pressure on structure and properties of fluoropolymer coatings by hot wire CVD

... The present work aims to study the possibilities of controlling the properties of fluoropolymer coatings deposited by Hot Wire Chemical Vapor Deposition (HWCVD) or CatCVD [4-6]. The method allows to control ...

5

Experimental study of the flow field disturbance in the vicinity of single sensor hot-wire anemometer

Experimental study of the flow field disturbance in the vicinity of single sensor hot-wire anemometer

... normal hot-wire anemometer (SN) probe was carried ...the wire and its strong dependence on both – the velocity magnitude and the probe orientation in relation to freestream ...

6

Investigation of the velocity field downstream of a benchmark vent using numerical simulation and hot-wire anemometry

Investigation of the velocity field downstream of a benchmark vent using numerical simulation and hot-wire anemometry

... Abstract. The velocity field in the area behind the automotive vent was measured by hot-wire anenemometry in detail and intensity of turbulence was calculated. Numerical simulation of the same flow field ...

6

A pilot study of hot wire, ultrasonic and wedge bellows spirometer inter  and intra variability

A pilot study of hot wire, ultrasonic and wedge bellows spirometer inter and intra variability

... four hot-wire (Vmax Encore 22D, Carefusion, Vmax Encore 22D, Vmax Encore 22, Vmax Spectra 229, SensorMedics, referred to as HW1-HW4), two ultrasonic (Spirare SPS320 sensors, Diagnostica AS, referred to as ...

7

Non-isothermal flow of air in a vertical tube: An experimental study with the hot-wire anemometer.

Non-isothermal flow of air in a vertical tube: An experimental study with the hot-wire anemometer.

... of hot-wire anemometers in low speed ...stable hot-wire system which could be used as a standard device for the calibra­ tion of other instruments in the speed range ...The ...

117

Thermal conductivity measurement in clay dominant consolidated material by Transient Hot-Wire method.

Thermal conductivity measurement in clay dominant consolidated material by Transient Hot-Wire method.

... the Hot Wire Method, already validated in fluids appears to be well adapted to thermal conductivity measurement in solid and clay dominant ...the Hot Wire Method developed to the thermal ...

8

Constant temperature hot wire anemometry applied to the characterisation of a nozzle molecular beam source

Constant temperature hot wire anemometry applied to the characterisation of a nozzle molecular beam source

... This document details the modification of the supersonic fuelling system on the H-1 experiment. The existing converging-diverging nozzle with a 0.35mm throat diame- ter was replaced with a converging-diverging nozzle ...

127

Evaluation of Ernicrfe 7A Filler Wire for Dissimilar Welding of SS304H & T91 Material using Hot Wire Tig Welding Process

Evaluation of Ernicrfe 7A Filler Wire for Dissimilar Welding of SS304H & T91 Material using Hot Wire Tig Welding Process

... the Hot-wire Gas Tungsten Arc welding process has been ...the Hotwire Gas Tungsten process is shown in the ...by wire brush in between ...

6

Comparison of Properties of Super 304H Tube Welded by Manual and Semiautomatic Hot Wire GTAW

Comparison of Properties of Super 304H Tube Welded by Manual and Semiautomatic Hot Wire GTAW

... © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 977 SEM micrographs of the filler-added weld joint are reveals randomly oriented fully austenitic dendritic grains. The SEM image was ...

10

Low-temperature hot-wire chemical vapor deposition of epitaxial films for large-grained polycrystalline photovoltaic devices

Low-temperature hot-wire chemical vapor deposition of epitaxial films for large-grained polycrystalline photovoltaic devices

... This thesis is organized first with a brief introduction into the photovoltaics market, the drive for thin-film solar cells, and the current status of large-grained polycrystalline devices. Chapter 2 is a summary of ...

162

Measurement of Thermal Conductivity of Magnesia Brick with Straight Brick Specimens by Hot Wire Method

Measurement of Thermal Conductivity of Magnesia Brick with Straight Brick Specimens by Hot Wire Method

... the hot wire versus the logarithm of time log t as measured at different temperatures with the hot wire method using magnesia brick ...the hot wire has a certain mass, and part of ...

8

Visualization of Hot Wire Gas Tungsten Arc Welding Process

Visualization of Hot Wire Gas Tungsten Arc Welding Process

... for hot wire addition is similar to the cold wire process, except that the wire is resistance heated nearly to its melting temperature at the point of contact with the weld ...preheated ...

6

An Adaptive Response Compensation Technique for the Constant Current Hot Wire Anemometer

An Adaptive Response Compensation Technique for the Constant Current Hot Wire Anemometer

... different hot-wire probes consist- ing of tungsten wires 5 μm, 10 μm and 20 μm in ...the hot-wire ...the hot-wire probe, and will realize adaptive response com- pensation of the ...

14

Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

Airflow Measurement of the Car HVAC Unit Using Hot-wire Anemometry

... The aim of this study was to develop a methodology to measure airflow within a vehicle HVAC system simply and relatively precisely. Inlet and outlet HVAC airflows were studied exploiting hot wire ...

6

Hot wire chemical vapor deposition of silicon and silicon nitride for photovoltaics: experiments, simulations, and applications

Hot wire chemical vapor deposition of silicon and silicon nitride for photovoltaics: experiments, simulations, and applications

... The residence time distribution was determined by applying a pulse input (i.e., quickly opening and closing a leak valve) of a mixture of argon diluted in helium (1%) to the hot-wire reactor and monitoring ...

212

Response of an anemometer with an oscillating hot-wire.

Response of an anemometer with an oscillating hot-wire.

... a hot-wire is subjected to a sinusoidal velocity in a stagnant fluid (air), the output voltage is expected to be a rectified sine ...The hot-wire output would therefore have twice as many ...

119

A HOT-WIRE ANEMOMETER FOR PARTICLE COUNTERS

A HOT-WIRE ANEMOMETER FOR PARTICLE COUNTERS

... In recent years, the public is finding that air quality plays a vital role in the health of those exposed [1-4]. Yet, real-time monitoring remains largely inaccessible to the vast majority of the public. In order to ...

107

An approach for Measuring Thermal Conductivity of Bricks using Transient Hot Wire method

An approach for Measuring Thermal Conductivity of Bricks using Transient Hot Wire method

... transient hot wire (THW) technique. This hot wire method has been developed for measurements in electro conducting liquid [14-15] and in highly corrosive liquids ...transient hot ...

6

Show all 4933 documents...

Related subjects