• No results found

line current harmonics mitigation

Mitigation of Current and Voltage Harmonics using MAF based UPQC

Mitigation of Current and Voltage Harmonics using MAF based UPQC

... compensating current references applied to a three-phase line-interactive UPS ...and/or current of the abc-phase stationary reference frame are transformed into continuous quantities into the dq ...

6

id iq Control Strategy for Mitigation of Current Harmonics with Fuzzy Logic Controller Using Matlab/Simulation and RTDS Hardware

id iq Control Strategy for Mitigation of Current Harmonics with Fuzzy Logic Controller Using Matlab/Simulation and RTDS Hardware

... and current waveform distortions are ...non-sinusoidal current [1] results in many problems for the utility power supply company, such as: low power factor, low energy efficiency, electromagnetic in- ...

12

A Novel Scheme of Harmonics Mitigation by Using Single Tuned and Double Tuned Passive Harmonics Filters

A Novel Scheme of Harmonics Mitigation by Using Single Tuned and Double Tuned Passive Harmonics Filters

... particular harmonics so that these harmonics distortion are diverted from their normal flow path through the filter or is tuned to present high impedance to particular harmonics to stop them from ...

9

Mitigation of Harmonics Using Active Power Filters Based on Hysteresis Current Control

Mitigation of Harmonics Using Active Power Filters Based on Hysteresis Current Control

... Hysteresis Current control block has been implemented for the shunt active power ...and harmonics due to non linear load. The THD of source current after compensation is ...

9

Mitigation of Voltage and Current Harmonics using UPQC Base on Synchronous Reference Frame Method

Mitigation of Voltage and Current Harmonics using UPQC Base on Synchronous Reference Frame Method

... compensating current and voltage references applied to a three-phase line-interactive UPS ...and current required to compensate the voltage and current ...and/or current signals in ...

5

Mitigation of Voltage sag and Current Harmonics Using UPQC base PEMFC

Mitigation of Voltage sag and Current Harmonics Using UPQC base PEMFC

... the line voltage frequency using (4) and (5).The line frequency components of the load currents become DC quantities and the harmonic components are frequency shifted by ωt in the d-q reference ...

5

Mitigation of Harmonics using D STATCOM

Mitigation of Harmonics using D STATCOM

... the harmonics, which are introduced due to non-linearity or unbalance of ...these harmonics custom power devices can be ...power line conditioner for power quality improvements such as current ...

5

Estimation and Mitigation of Current and Voltage Harmonics in Distribution System Using Distributed Generation

Estimation and Mitigation of Current and Voltage Harmonics in Distribution System Using Distributed Generation

... additional line losses and core loss in ...concern. Harmonics, the meter may register maximum or minimum depending on the harmonic distortion present and the response of the ...

7

Three Phase Grid Connected PV System for Mitigation of Voltage and Current Harmonics Compensation Using SRF Method

Three Phase Grid Connected PV System for Mitigation of Voltage and Current Harmonics Compensation Using SRF Method

... The series active filter compensates the harmonic voltage by synchronous reference frame (SRF) -based controllers. The shunt active filter compensates the harmonic currents by using synchronous reference frame (SRF) ...

9

Mitigation of Harmonics by Using Active and Passive Harmonics Filters as well as faults Detect by Using MATLAB Simulation

Mitigation of Harmonics by Using Active and Passive Harmonics Filters as well as faults Detect by Using MATLAB Simulation

... filter designed. The passive filter is a very good choice for constant loads and is a cost effective solution to harmonic reduction and power factor improvement. All these advantages can be lost if the input filter is ...

10

A Study of  Hysteresis Band Current Control Scheme For Shunt Active Power Filter Used For Harmonics Mitigation

A Study of Hysteresis Band Current Control Scheme For Shunt Active Power Filter Used For Harmonics Mitigation

... The performance of active filter is dependent on two parts: current control system and harmonic reference generation. The development of compensating signals in terms of voltages or currents is the important part ...

6

Mitigation of Harmonics for Grid-inter Connected DG system

Mitigation of Harmonics for Grid-inter Connected DG system

... [18] H. Chaoyong, H. Xuehao, and H. Dong, "Hierarchical control techniques applied in micro- grid," in Power System Technology (POWERCON), 2010 International Conference on, 2010, pp. 1-5. [19] J. M. Guerrero, J. ...

5

Modelling and Simulation of Current Source Converter based Dynamic Voltage Restorer for Voltage Regulation cum Harmonics Mitigation

Modelling and Simulation of Current Source Converter based Dynamic Voltage Restorer for Voltage Regulation cum Harmonics Mitigation

... The DVR is a versatile series connected power electronic converter based CPD which is capable of protecting sensitive loads from all supply-side disturbances except outages [1]. In other words, it can be used for solving ...

7

A Design of Active Power Filter for Superconducting Nanowire Single-Photon Detectors

A Design of Active Power Filter for Superconducting Nanowire Single-Photon Detectors

... Abstract: The basic structure and working principles of superconducting nanowire single-photon detectors (SNSPD) are described in this paper. The special requirements for power quality of the system are introduced in ...

7

Three phase Shunt Active power filter for harmonic reduction in non linear loads

Three phase Shunt Active power filter for harmonic reduction in non linear loads

... distorted line currents adapting themselves to the load changes and to changing in working ...the line current to be in phase and of the same shape as the supply ...

6

Fuzzy and PI Controller Based SHAF for Mitigation of Current Harmonics with P Q Method Using Matlab and RTDS Hardware

Fuzzy and PI Controller Based SHAF for Mitigation of Current Harmonics with P Q Method Using Matlab and RTDS Hardware

... Figure 5 shows the internal structure of the control cir- cuit. The control scheme consists of Fuzzy controller [14], limiter, and three phase sine wave generator for reference current generation and generation of ...

15

Harmonic Current Reduction by Using the Super Lift Boost Converter for Two Stage Single Phase Inverter

Harmonic Current Reduction by Using the Super Lift Boost Converter for Two Stage Single Phase Inverter

... increased current initially, it heats up faster its resistance rises and this increased resistance causes this current to shift to other devices in ...

6

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

... voltage harmonics are compensated by series inverter connected to the line in ...series.The current related problems like current harmonics are solved by shunt inverter connect to the ...

7

Doubly Fed Induction Generator Based Wind Turbine Associated to a Shunt Active Power Filter for Current Harmonics Mitigation

Doubly Fed Induction Generator Based Wind Turbine Associated to a Shunt Active Power Filter for Current Harmonics Mitigation

... these harmonics in the ...the current harmonics caused by the connection of nonlinear loads at the point of common coupling ...mitigate current harmonics so that wind turbines can ...

7

A Dual Control Strategy for Phase Balancing in Three Phase Four Wire Distribution Systems by Artificial Neural Network

A Dual Control Strategy for Phase Balancing in Three Phase Four Wire Distribution Systems by Artificial Neural Network

... strategies; current control strategies (id– iq) with PI and ANN with PI have been implemented for the three-phase four-wire distribution system to improve the performance under balanced, un-balanced and non-ideal ...

7

Show all 10000 documents...