• No results found

line-current harmonics reduction

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

... ac line voltage and filtering it with large ...input current which reduces the power ...pulsating current from the AC mains are the main disadvantages of the diode rectifier and phase controlled ...

9

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

A Reduction of harmonics at the Interface of Distribution and Transmission Systems by using Current Source active Power Filter

... harmonic current component in αβ coordinates are then multiplied by the associated constant 1/G5 of the Gain Adjustment block in ...transformer’s line-to-line voltage ratio, n and shifted by θn in ...

5

Reduction of Harmonics by Using Active and Passive Harmonics Filters

Reduction of Harmonics by Using Active and Passive Harmonics Filters

... particular harmonics so that these harmonics distortion are diverted from their normal flow path through the filter or is tuned to present high impedance to particular harmonics to stop them from ...

9

Active Current Harmonics Reduction Control for Power Factor Correction in IPMSM Drive System

Active Current Harmonics Reduction Control for Power Factor Correction in IPMSM Drive System

... increased current and voltage transients on the line side are passed back through the PFC capacitors causing increased operating voltage and current, which produces higher operating temperatures and ...

13

Design Of Dynamic Voltage Restorer For Three Phase Network As Steady State Device In The Distribution System

Design Of Dynamic Voltage Restorer For Three Phase Network As Steady State Device In The Distribution System

... voltage [9] [10]. The Dynamic Voltage Restorer (DVR) operates in standby mode in normal conditions whereas in case of disturbances variation in the output voltage occurs [11] [12]. Inspite of voltage sags and swells ...

5

Three phase Shunt Active power filter for harmonic reduction in non linear loads

Three phase Shunt Active power filter for harmonic reduction in non linear loads

... low current total harmonic distortion, reactive power compensation, is ...damp harmonics produced by a diode ...the line current to be in phase and of the same shape as the supply ...

6

Harmonics Reduction in Power Supply using DPFC                       

Harmonics Reduction in Power Supply using DPFC                       

... voltage, current and frequency that makes the power failures ...inrush current has been expanded, and switching issues have been happened in grid ...transmission line [6]. A STATCOM is utilized as a ...

7

Reduction of Current Harmonics with FLC based CSC for Synchronous Drive

Reduction of Current Harmonics with FLC based CSC for Synchronous Drive

... Improving power quality considerations require two factors: achieving high power factor and low harmonics. In fact, a low power factor reduces the power available from the utility grid, while a huge harmonic ...

11

Harmonics Reduction

Harmonics Reduction

... From the above analysis the line current THD increase and will not meet the requirements of the harmonic standard limitations. This trade off relation between the power factor and the current THD is ...

5

Reduction of So Urce Current Harmonics in an Inverter Fed Induction Motor with an Input Active Filter Along with PI Controller

Reduction of So Urce Current Harmonics in an Inverter Fed Induction Motor with an Input Active Filter Along with PI Controller

... actual current. The point where sinusoidal triangular wave and actual current cross becomes time when inverter leg is ...different current ripples in one inverter ...load current. This method ...

6

Improvement of Power Quality by Reduction of Harmonics

Improvement of Power Quality by Reduction of Harmonics

... The reduction of harmonics in this side is becoming mandatory for Engineers in recent ...The harmonics mostly generate in low voltage side due to connection of non-linear ...generated ...

8

Analysis and control of voltage harmonics generated by thyristor controlled series capacitors

Analysis and control of voltage harmonics generated by thyristor controlled series capacitors

... The main drawbacks of TCSC are the nonlinear effects on system stability, discrete (non-continuous) impedance and harmonics injection. It is known that harmonic currents and the resulting harmonic voltages can be ...

9

Minimization of Torque Ripples for PMBLDC Motor Drive Using Simplified IFOC Based H-Bridge Multi Level Inverter

Minimization of Torque Ripples for PMBLDC Motor Drive Using Simplified IFOC Based H-Bridge Multi Level Inverter

... +ve current flow and Q6, Q2,Q4 are –ve ...still current flowing on the machine coils due to the last driving stage as indicated by the free-wheeling ...the current harmonic in rotor is the other ...

10

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

Unified Power Quality Conditioner (UPQC) in Alleviation of Power Quality Issues

... and current deformity ...Alternating current Transmission) circuit called UPQC (unified power quality conditioner) is developed to compensate the voltage and current ...with current harmonic ...

7

Harmonic Current Reduction by Using the Super Lift Boost Converter for Two Stage Single Phase Inverter

Harmonic Current Reduction by Using the Super Lift Boost Converter for Two Stage Single Phase Inverter

... increased current initially, it heats up faster its resistance rises and this increased resistance causes this current to shift to other devices in ...

6

Multilevel Inverter for Eliminating Harmonics in Line To Line Voltage Using Genetic Algorithm

Multilevel Inverter for Eliminating Harmonics in Line To Line Voltage Using Genetic Algorithm

... harmonic reduction characteristics of the output AC voltage under the utilization ratio of different modulation, and achieve optical control of output waveform by different modulation ...

6

Simulation on Harmonic Suppressions of A Square Ring Resonator by Two Spurlines

Simulation on Harmonic Suppressions of A Square Ring Resonator by Two Spurlines

... A square ring resonator is shown in Fig. 1. The substrate material is Rogers TMM10i with a relative dielectric constant of 9.8 and a loss tangent of 0.002. The thickness of the substrate is 1.27 mm. The whole backside of ...

6

Suppression of Harmonics and Neutral-Line Current by Hybrid Power Conditioner in Three-Phase Four-Wire Distribution Power Systems

Suppression of Harmonics and Neutral-Line Current by Hybrid Power Conditioner in Three-Phase Four-Wire Distribution Power Systems

... harmonic current pollution and large neutral-line ...neutral- line current attenuator, is ...neutral-line current attenuator can be effectively reduced, thus increasing its use ...

8

Improvement of Power Quality by Reduction of Harmonics

Improvement of Power Quality by Reduction of Harmonics

... Fig 5 shows that; the designed filter is connected in between Inverter and the non-linear load. The filter is a LC filter. The total harmonic distortion value will be very much reduced on connecting this filter. The ...

7

Power Quality Audit at SAEC Using the Fluke 435 II Series

Power Quality Audit at SAEC Using the Fluke 435 II Series

... are harmonics, voltage unbalance, the reasons for this power quality issues are usage of CFL’s , computer, electronic kits in lab, SMPS, ...THD current are exceedind the limit provided by IEEE ...

7

Show all 10000 documents...