DIESEL GENERATOR EMPLOYED D-STATCOM FOR ISOLATED GENERATION SYSTEM TO COMPENSATE LOAD BY USING PI AND NEURO-FUZZY CONTROLLERS

DIESEL GENERATOR EMPLOYED D-STATCOM FOR ISOLATED GENERATION SYSTEM TO COMPENSATE LOAD BY USING PI AND NEURO-FUZZY CONTROLLERS

... the control of distribution static synchronous compensator (DSTATCOM) for reactive power, harmonics and unbalanced load current compensation of a diesel generator set for an isolated ...The ...

7

Study of Power Quality by using Different Power Circuit Topology & Control Scheme in UPQC

Study of Power Quality by using Different Power Circuit Topology & Control Scheme in UPQC

... new control strategy used in the UPQC system, which mainly compensate reactive power and voltage and current harmonics in the load under non-ideal mains voltage and unbalanced load ...

9

Fractional Order PI based UPQC for Improvement of Power Quality in Distribution Power System

Fractional Order PI based UPQC for Improvement of Power Quality in Distribution Power System

... of load voltage harmonics, current harmonics, voltage swell, sag and THD of nonlinear loads, a FOPI based UPQC proposed to tackle Power Quality ...novel control strategy known as ...

6

Implementation Of Adaptive Filter In Dstatcom

Implementation Of Adaptive Filter In Dstatcom

... sinusoidal current in a distribution system is mainly due to nonlinear characteristics of equipment such as adjustable speed drives, switch- mode power supplies, rectifiers, and others such type of loads ...

9

PMSM Drive Based D-STATCOM in Combination with Renewable Energy Sources to Enhance Power Quality

PMSM Drive Based D-STATCOM in Combination with Renewable Energy Sources to Enhance Power Quality

... of harmonics in industrial distribution systems. Hysteresis loss current control algorithm utilizes the error signal which is the difference between the reference voltage and actual measured ...

8

Reduction of Current Harmonics Using SVPWM Control for Shunt Active Filter

Reduction of Current Harmonics Using SVPWM Control for Shunt Active Filter

... the current distortion is therefore a concern for both utilities and ...of harmonics. This harmonics can be reduced by using the shunt active ...many control strategies to reduce ...PWM ...

5

Mitigation of Total Harmonic Distortion for UPQC Based DFIG System Using Various Controllers

Mitigation of Total Harmonic Distortion for UPQC Based DFIG System Using Various Controllers

... the load current harmonics are simulated by connecting Diode bridge rectifier load in the proposed grid connected wind power ...proposed control strategy using FLC is implemented for ...

8

Efficient Control of Shunt Active Power Filter with Self- Adaptive Filter Using Average Power Algorithm

Efficient Control of Shunt Active Power Filter with Self- Adaptive Filter Using Average Power Algorithm

... harmonic current generated by power electronic equipment has become important because of its growing use in industrial ...the load current harmonics current effectively, the Shunt ...

6

Adaptive Filter Implementation Based Control Algorithm for Distribution Static Compensator

Adaptive Filter Implementation Based Control Algorithm for Distribution Static Compensator

... alternating current (AC). However, alternating current has various definite ...of load centers and hundreds of generating stations are interconnected through long power transmission and distribution ...

10

Hybrid Active Filter With Variable Conductance For Harmonic Suppression

Hybrid Active Filter With Variable Conductance For Harmonic Suppression

... proposed control strategy is simulated with a non-linear balanced load and the performance of the system is ...proposed control strategy is simulated and the circuit diagrams with RL and in ...the ...

10

Harmonic Reduction in Wind Energy Systems Using FLC and PI based Shunt Active Filter

Harmonic Reduction in Wind Energy Systems Using FLC and PI based Shunt Active Filter

... the load. It has the capability to inject harmonic current into the AC system with the same amplitude but opposite in phase with the load ...of load harmonic current i.e. it confines ...

6

Power Quality Improvement using Active shunt Power filter using PI Controller

Power Quality Improvement using Active shunt Power filter using PI Controller

... called load conditioning, which ensures that the equipment is made less sensitive to power disturbances, allowing the operation even under significant voltage ...few harmonics, and they can introduce ...

6

SYMMETRIC CRYPTOGRAPHY KEYS MANAGEMENT FOR 6LOWPAN NETWORKS

SYMMETRIC CRYPTOGRAPHY KEYS MANAGEMENT FOR 6LOWPAN NETWORKS

... In this paper, an optimal method for tuning the PI parameters in DC voltage regulator of grid- connected inverter system is presented. Recently, ant colony algorithm is applied in various fields, such as power grid ...

7

Vol 2, No 11 (2014)

Vol 2, No 11 (2014)

... 2) load reactive power demand support; 3) current harmonics compensation at PCC; and 4) current unbalance and neutral current compensation in case of 3-phase 4- wire ...adequate ...

6

Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter

Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter

... band current controller (HBCC) is proposed for limiting the harmonics in load current and also compensate the reactive power linear ...suitable current reference ...SAPF control ...

5

Artificial Neural Network Controlled Shunt Active Power Filter For Power Quality Improvement

Artificial Neural Network Controlled Shunt Active Power Filter For Power Quality Improvement

... sensing harmonics and reactive volt-ampere requirements of the non-linear ...complex control. In some active filters, both phase voltages and load currents are transformed into the α-β orthogonal ...

7

Grid Interfaced Renewable Energy Source to Improve Power Quality Using SAPF

Grid Interfaced Renewable Energy Source to Improve Power Quality Using SAPF

... the load but 180° phase shifted. The harmonics inserted into the line are eliminated and utility supply become ...the control techniques, the inverter act and inject the compensating harmonics ...

6

Harmonic Mitigation using D-STATCOM with Renewable Energy Sources for improved Power Quality using Intelligent Controller Dr. N. Samba Siva Rao 1, Mochi Lavanya Devi Bai2

Harmonic Mitigation using D-STATCOM with Renewable Energy Sources for improved Power Quality using Intelligent Controller Dr. N. Samba Siva Rao 1, Mochi Lavanya Devi Bai2

... like current harmonics, current unbalance due to unbalanced and non linear load connected to the PCC is compensated effectively by using shunt active power filter ...hysteresis current ...

9

A Three Phase Shunt Active Power Filter For Harmonics Reduction

A Three Phase Shunt Active Power Filter For Harmonics Reduction

... the current regulators and the DC-link voltage ...as current response delay generated by the boost inductors and DC-link voltage feedback delay due to the detecting ...

5

Series Active Power Filter for Power Quality Improvement

Series Active Power Filter for Power Quality Improvement

... A number of solutions square measure accessible within the gift day apply like power issue correction system with detuned filter, electrical device banks and series reactors to mitigate harmonics, improve power ...

7