• No results found

load-tap-changing transformers

Maximising wind generation through optimised operation of on-load tap changing transformers in active distribution networks

Maximising wind generation through optimised operation of on-load tap changing transformers in active distribution networks

... On-load tap changing transformers are the most common control device to regulate and maintain distribution network voltage within required ...the tap changer is operated at the ...

6

Automatic control of On Load Tap Changing of Transformers for Enhancement of Voltage Stability

Automatic control of On Load Tap Changing of Transformers for Enhancement of Voltage Stability

... after tap-changing is used to estimate simple TCSI which is used to provide the stability of on load tap changing of ...with load shedding, with capacitor bank injection and with ...

9

Analysis of the Effect of Tap Changing Transformer on Performance of SVC

Analysis of the Effect of Tap Changing Transformer on Performance of SVC

... Some of these studies were interested in proposing new models of tap-changing transformers. On the other hand, Static VAR compensator is used for improvement of voltage stabilities [6,7,8] due to ...

8

Comparison Study of Different Methods of on Load Tap Changer

Comparison Study of Different Methods of on Load Tap Changer

... more transformers are connected in ...But transformers, with on-load tap changing capability, are quite commonly applied to regulated bus voltage for a long ...on-load tap ...

6

Co-Ordination of SVC and on Load Tap Changing Transformer for Reactive Power Control in Power Systems

Co-Ordination of SVC and on Load Tap Changing Transformer for Reactive Power Control in Power Systems

... Most power systems are nowadays operated very near to their operating limits due to increase in consumption, while economic and environmental constraints have limited construction of new generation facilities and lines. ...

6

On Line Independent Tap Changing of Each Feeder Supplied by a Low Voltage Distribution Transformer

On Line Independent Tap Changing of Each Feeder Supplied by a Low Voltage Distribution Transformer

... The tap-changing system was tested under a range of conditions, focusing on those where there is a large load- ing/generation differential between ...Independent tap setting was able to keep ...

7

Increasing cost efficiency through minimizing transformer losses: Design and performance analysis of a 250 kVA off-load tap changing step down transformer

Increasing cost efficiency through minimizing transformer losses: Design and performance analysis of a 250 kVA off-load tap changing step down transformer

... In this paper agitated in regard to design hermetically sealed shell type oil immersed distribution transformers with minimum evaluated cost according to the IEC standards. Here very calculatedly describe about ...

9

Impact of Tap Changing Transformers on the Loss Minimization of Electrical Power Distribution System Ganiyu A. Ajenikoko, Anthony A. Olaomi

Impact of Tap Changing Transformers on the Loss Minimization of Electrical Power Distribution System Ganiyu A. Ajenikoko, Anthony A. Olaomi

... before tap changing, even though the reactive power losses fluctuated among the ten selected feeders used in the ...highest load of 5.9MVAr on St. Gorald feeder and a least load of ...total ...

10

A new arc-based model and condition monitoring algorithm for on-load tap-changers

A new arc-based model and condition monitoring algorithm for on-load tap-changers

... permissible tap-changing operations with respect to different current, power, and arcing energy ...of tap-changing operations without considering the effect of different loading conditions ...

25

Tap Changing in Parallel Operated Transformers Using SCADA

Tap Changing in Parallel Operated Transformers Using SCADA

... more transformers are connected in ...of transformers. On load tap changer is used to regulate the system voltage while the transformer is delivering the normal load by varying the ...

5

Effect of Climate Change on Transformers Loading Conditions in the Future Smart Grid Environment

Effect of Climate Change on Transformers Loading Conditions in the Future Smart Grid Environment

... Distribution Transformers The data for secondary line transformers is given in Ap- pendix 1 ...between load losses at rated current to no load losses. The load losses at rated current ...

6

Evaluation Study of Performance Analysis & Characteristics of Amorphous Core Transformer for Electrical Distribution System Prof. Kanchan Shriprakash Patil

Evaluation Study of Performance Analysis & Characteristics of Amorphous Core Transformer for Electrical Distribution System Prof. Kanchan Shriprakash Patil

... Distribution Transformers are the proven energy savers and this is because the Amorphous Metal core reduces the No load losses by about 75% when compared to the conventional CRGO ...

7

Transient Analysis of Large Scale Photovoltaic Plant Interacting with Active Distribution Loads.

Transient Analysis of Large Scale Photovoltaic Plant Interacting with Active Distribution Loads.

... With large scale photovoltaic plants and increasing distributed energy resources penetration in the existing power grid, utilities are facing a lot of issues and laborious challenges. Major concerns arise when the ...

94

Performance Analysis of UPQC for Non-Linear Load by Using MATLAB

Performance Analysis of UPQC for Non-Linear Load by Using MATLAB

... IJEDR1504005 International Journal of Engineering Development and Research (www.ijedr.org) 1 ________________________________________________________________________________________________________ Abstract - In this ...

6

Transformer monitoring and on load tap changer control using programmable logic

Transformer monitoring and on load tap changer control using programmable logic

... and load tap changer control (LTC) as presented in this paper is implemented using programmable logic, math functions and IEC 61850 communications over fiber-optic ...to tap up, tap down, or ...

8

An Approach to Volt/Var Control in Distribution Networks with Distributed Generation

An Approach to Volt/Var Control in Distribution Networks with Distributed Generation

... Due to deregulation and restructuring in many countries, it is expected that the amount of small- scale generations connected to the distribution networks will increase. So, it is necessary that the impact of these kinds ...

9

APPLICATION OF FITNESS SWITCHING GENETIC ALGORITHM FOR SOLVING 0 1 KNAPSACK 
PROBLEM

APPLICATION OF FITNESS SWITCHING GENETIC ALGORITHM FOR SOLVING 0 1 KNAPSACK PROBLEM

... peak load forecasting of the Bumiayu substation ...peak load transformer based on GUI Matlab using Backpropagation type Neural ...electric load forecasting that can be used as input material and ...

11

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

... padmounted transformers feature a tamper resistant construction with no externally accessible bolts, hinges, screws or fasteners, thus providing a safe, self-contained unit which cannot be accessed by unauthorised ...

51

A novel multi modular series HVDC tap

A novel multi modular series HVDC tap

... A novel n-phase modular multilevel series HVDC tap method has been proposed. Full-bridge sub-module arms are connected in series with HVDC line to exchange power between the HVDC line and MVAC load. A ...

6

A Content-based Dynamic Load-Balancing Algorithm for Heterogeneous Web Server Cluster

A Content-based Dynamic Load-Balancing Algorithm for Heterogeneous Web Server Cluster

... content-based load- balancing ...lowest load according to the degree of effects on the server and a combination of load state of ...the load of web server clusters effectively, make full use ...

10

Show all 10000 documents...