Characterization Method of an Automotive Random-LOS OTA Measurement Setup

Characterization Method of an Automotive Random-LOS OTA Measurement Setup

... characterization method for measurement setups intended for OTA measurements of the automotive wireless communication systems in Random-LOS ...characterization method, a measurement ...

14

Optimization of the Neutron Absorption Steady Source Measurement Method --by using an 124Sb-Be Source

Optimization of the Neutron Absorption Steady Source Measurement Method --by using an 124Sb-Be Source

... the source- sample center line for the initial calibration of the steady source ...steady source experiment simulation the antimony source is specified as a uniform source with the ...

80

The Activation Detector Activity Calculations Using the Effective Source Method and Measurement

The Activation Detector Activity Calculations Using the Effective Source Method and Measurement

... the source data by time dependent depletion of the detector activity, the result of the calculation is the detector ...the source data are referred to as the ‘effective ...effective source ...

5

Construction of Sheet Resistance Measurement Setup for Tin Dioxide Film Using Four Probe Method

Construction of Sheet Resistance Measurement Setup for Tin Dioxide Film Using Four Probe Method

... current source is an electronic circuit that delivers or absorbs an electric current which is independent of the resistance across ...current source is the dual of a voltage ...current source (or ...

6

Sub Criticality Measurement with Source Term for Research Reactor in Inverse Kinetics Method

Sub Criticality Measurement with Source Term for Research Reactor in Inverse Kinetics Method

... kinetics method are widely used during the operation of a nuclear ...neutron source where the neutron source term in point reac- tor kinetics equations may be ...neutron source may not be ...

7

Development Of An Experimental Setup For Emissivity Measurement At Cryogenic Temperatures

Development Of An Experimental Setup For Emissivity Measurement At Cryogenic Temperatures

... Cryopump is an entrapment vacuum pump that retains the gas molecules by sorption and or condensation on their internal surfaces at low temperatures. This pumping effect is caused by the interaction between the gas ...

6

Measurement setup for differential-mode and common-mode channels

Measurement setup for differential-mode and common-mode channels

... They recall the MacFarlane method and Van Maurik similar method. Finally [2] describes the paper of Tudziers and Paul where a method of calculating common-mode voltages on a telecommunication cable ...

5

Extended measurement setup for transient TEM waveguide characterization

Extended measurement setup for transient TEM waveguide characterization

... field measurement method, based on a two-antenna setup, to qualify the transmission of transient signals inside a GTEM ...same setup, another measurement is performed in frequency ...

6

Measurement of Average Thermal Neutron Flux for PGNAA Setup

Measurement of Average Thermal Neutron Flux for PGNAA Setup

... PGNAA setup for an element depends upon the neutron flux available at ...of setup for different sample configuration and second, to determine the average neutron thermal flux at the sample of the PGNAA ...

6

Impedance-based analysis of 3D tissue models: A novel measurement setup for novel measurement modes

Impedance-based analysis of 3D tissue models: A novel measurement setup for novel measurement modes

... the method of choice to conduct non-invasive and label-free investigations of monolayer cells and tissue ...ment setup for impedimetric analysis of 3D tissue models was tested and compared with the standard ...

260

A Substituted Method for TRP Measurement

A Substituted Method for TRP Measurement

... Typical TRP Test Configuration Figure 1. A typical TRP test configuration. In the test setup described above, a base station simulator is required, such as CMW500, CBT, etc. However, some wireless communication ...

5

II. LTEC MEASUREMENT METHOD

II. LTEC MEASUREMENT METHOD

... sample-free method for determination of the linear thermal expansion coefficient (LTEC) and the speckle- interferometer setup are ...The method and setup were evaluated using samples from a ...

6

Variation in Outcomes of Quality Measurement by Data Source

Variation in Outcomes of Quality Measurement by Data Source

... quality measurement technical speci fi cations to include au- tomated extraction of data from dis- crete EHR data fi elds, in addition to (or in place of) a manual chart review hy- brid ...

9

Evaluation of a Substitution Method for Idiom Transformation in Statistical Machine Translation

Evaluation of a Substitution Method for Idiom Transformation in Statistical Machine Translation

... a source sen- tence, then ‘mentally’ replaces that idiom with its literal ...proposed method, we see it as plausible and have developed a compu- tational method based on this work-flow and the ...

5

Evaluation of a Substitution Method for Idiom Transformation in Statistical Machine Translation

Evaluation of a Substitution Method for Idiom Transformation in Statistical Machine Translation

... a source sen- tence, then ‘mentally’ replaces that idiom with its literal ...proposed method, we see it as plausible and have developed a compu- tational method based on this work-flow and the ...

6

Automatic Test Setup for Measurement and Characterization of Accelerating Cavity Using LabVIEW

Automatic Test Setup for Measurement and Characterization of Accelerating Cavity Using LabVIEW

... Bead-Pulling Measurement Pulling Measurement (Multi-cell Cavity Field Flatness) Prepared by Sung-Woo Lee ...Antiproton Source Department, Accelerator Division Fermi National Accelerator Laboratory ...

8

Experimental setup and procedure for the measurement of the ⁷Be(n,p)⁷ Li reaction at n_TOF

Experimental setup and procedure for the measurement of the ⁷Be(n,p)⁷ Li reaction at n_TOF

... neutron source at CERN, several experiments were planned and ...successful measurement of the 7 Be(n,𝛼)𝛼 cross section, the 7 Be(n,p) 7 Li reaction was studied in order to provide still missing cross ...

7

Measurement of intertemporal substitution under nonseparable and nonhomothetic utility : the case of import demand

Measurement of intertemporal substitution under nonseparable and nonhomothetic utility : the case of import demand

... The budget share of imported goods reported in this paper is large compared to those reported by other studies. For example, Amano et al. (1998) report budget shares of around 1% in 1967 and around 4.7% in 1993 for ...

30

On a Simple Technique to Measure the Airborne Noise in a Motor Vehicle using Source Substitution

On a Simple Technique to Measure the Airborne Noise in a Motor Vehicle using Source Substitution

... Fig. 4 shows the experiment setup to obtain the SPL of the interior noise. The microphone was now located in the cabin at the driver‟s ear position as shown in Fig. 5. The procedures were the same as in the ...

6

Method for polarization-resolved measurement of electroabsorption

Method for polarization-resolved measurement of electroabsorption

... accurate method that uses a compact segmented contact structure to measure the absorption ...The method is based on measuring the transmission of amplified spontaneous emission (ASE) from a single ...