• No results found

synchronous generator excitation control

 INTELLIGENT SELF TUNING PID CONTROLLER USING HYBRID IMPROVED PARTICLE 
SWARM OPTIMIZATION FOR ULTRASONIC MOTOR

 INTELLIGENT SELF TUNING PID CONTROLLER USING HYBRID IMPROVED PARTICLE SWARM OPTIMIZATION FOR ULTRASONIC MOTOR

... pitch control using either a permanent magnet synchronous generator (PMSG) or a doubly fed induction generator is preferred by most of the manufacturers ...dc excitation system[5]; ...

10

Simulation of Power Tracking Scheme Through Excitation Synchronous Wind Power Generator

Simulation of Power Tracking Scheme Through Excitation Synchronous Wind Power Generator

... magnet synchronous generator, using MPPT (Maximum Power Point Tracking) control scheme with the help of regulating the dc link Voltage through Boost ...MPPT control scheme is applied by using ...

11

Excitation Synchronous Wind Power Generators with Maximum Power Tracking process

Excitation Synchronous Wind Power Generators with Maximum Power Tracking process

... the generator. Thus, therobust integral structure control (RISC) method is chosen toensure the voltage phase and the frequency in phase with ...servo control structure was chosen in theresearch ...

7

Synchronous generator transient behavior and protection under loss of excitation fault.

Synchronous generator transient behavior and protection under loss of excitation fault.

... the generator performance uhder short circuit in the field circuit using the two developed saturated and unsaturated models o f the generator will be ...The generator pre-fault working conditions are ...

81

Fundamental study and optimization of outer rotor hybrid excitation flux switching generator for grid connected wind turbine applications

Fundamental study and optimization of outer rotor hybrid excitation flux switching generator for grid connected wind turbine applications

... The DFIG is an induction machine with a wound rotor where the rotor and stator are both connected to electrical sources, hence the term ‘doubly-fed’. The rotor has three phase windings which are energized with ...

40

“Stability Criterion of a Processing Plant using PID Controller”

“Stability Criterion of a Processing Plant using PID Controller”

... process control system. It is necessary to maintain the control parameters by maintaining the voltage magnitude and frequency within the specified ...processing control system of plant behaves like ...

5

Permanent Magnet Synchronous Generator Wind Turbine Pitch Angle Control by Fuzzy and PID Control

Permanent Magnet Synchronous Generator Wind Turbine Pitch Angle Control by Fuzzy and PID Control

... The PMSG is considered, in many study articles, a fine choice to be used in WECS, due to its self-excitation possessions, which allows operation at good power factor and efficiency. PMSG won't need energy supply ...

6

Voltage Control of Synchronous Generator Using PID  Fuzzy Logic Controller

Voltage Control of Synchronous Generator Using PID Fuzzy Logic Controller

... the synchronous generator constant even for the change in load, this is achieved by varying the field current flowing through the field coils of synchronous ...PID control structure is simple, ...

11

Development of GUI and Simulink for Determination of Storage System Capacity for Wind Power Generation

Development of GUI and Simulink for Determination of Storage System Capacity for Wind Power Generation

... magnet synchronous generator is a generator where the excitation field is provided by a permanent magnet instead of a ...system, control of reactive power and decrease in cost with ...

8

Physical Processes in the Damping of Electromechanical Oscillations of the Synchronous Machine with Magnitude-Phase Excitation Controller

Physical Processes in the Damping of Electromechanical Oscillations of the Synchronous Machine with Magnitude-Phase Excitation Controller

... the synchronous machine with magnitude-phase excitation controller (MPH-EC), using as input the terminal voltage phasor (complex output of the plant - the synchronous generator), are ...

8

Grid Interfacing Technologies for Distributed Generation and Power Quality Issues - A Review

Grid Interfacing Technologies for Distributed Generation and Power Quality Issues - A Review

... include synchronous generator, induction generator and power electronic converter ...using synchronous generator whereas solar PV, fuel cell ...

5

PMSG Wind Energy Conversion System: Modeling and Control

PMSG Wind Energy Conversion System: Modeling and Control

... the synchronous rotating reference frame; R a is the armature resistance; L d , L q are the ge- nerator inductance on the d-q axis; i d , i q are, respectively, the d- and q-axis components of current; u q , u d ...

11

Novel Fuzzy Based Modeling and Control of Direct Control Variable Speed Wind Turbine with Interior Permanent Magnet Synchronous Generator

Novel Fuzzy Based Modeling and Control of Direct Control Variable Speed Wind Turbine with Interior Permanent Magnet Synchronous Generator

... and control of interior permanent magnet (IPM) synchronous generator based grid connected variable speed wind turbine with maximum power extraction ...IPM synchronous generator. The ...

11

Performance of synchronous generator using pid  fuzzy logic controller

Performance of synchronous generator using pid fuzzy logic controller

... the control law for fuzzy logic controller, which performs the function of PID control efficiently, the concept of digital PID is ...of control systems are frequently faced with the task of adjusting ...

6

Simulink Modelling of Current Control of Induction Generator by Using Hybrid Active Filter in Wind Energy System

Simulink Modelling of Current Control of Induction Generator by Using Hybrid Active Filter in Wind Energy System

... induction generator and is transmitted to the grid by the stator ...the generator output power to its nominal value for high wind ...induction generator speed must be slightly above the ...

8

Stability Analysis of Time Delayed Generator Excitation Control System using Resultant Theory

Stability Analysis of Time Delayed Generator Excitation Control System using Resultant Theory

... Time Delays have become unavoidable in Power System due to the usage of measurement devices and communication links for transferring the control signals. This paper investigates the effect of time delays on the ...

6

Performance Analysis of Wind Energy Conversion System Using Fuzzy Logic Controller

Performance Analysis of Wind Energy Conversion System Using Fuzzy Logic Controller

... novel control strategy for the operation of direct driven Permanent Magnet Synchronous Generator (PMSG) based grid connected variable speed wind turbine ...the control of pitch angle, real and ...

11

A Robust Decentralized Sliding-Mode Control for a SMIB-SVC System

A Robust Decentralized Sliding-Mode Control for a SMIB-SVC System

... requirements, control and power system communities are designing structures in order to allow the generation and distribution of electrical energy more efficiently ...several control approaches have been ...

25

Isolated Wind Power Generation Employing PMSG with V-f Controller

Isolated Wind Power Generation Employing PMSG with V-f Controller

... magnet synchronous generator) system and the voltage and frequency are controlled using a controller consisting of insulated gate bipolar transistors (lGBTs) based voltage source converter (VSC) with a ...

9

Wind Energy Conversion System Connected With Grid Using Permanent Magnet Synchronous Generator (PMSG)

Wind Energy Conversion System Connected With Grid Using Permanent Magnet Synchronous Generator (PMSG)

... inverter control:- The genera tor side inverter is controlled to catch maximum power from available wind ...To control electromagnetic torque we have to control q axis current iqs with the assumption ...

8

Show all 10000 documents...

Related subjects