• No results found

[PDF] Top 20 Boundary Element formulation for Electrical Impedance Tomography

Has 10000 "Boundary Element formulation for Electrical Impedance Tomography" found on our website. Below are the top 20 most common "Boundary Element formulation for Electrical Impedance Tomography".

Boundary Element formulation for Electrical Impedance Tomography

Boundary Element formulation for Electrical Impedance Tomography

... cal Impedance Tomography (EIT), i.e. the computation of an electrical potential due to an applied boundary ...Neumann boundary condition. We introduce a symmetric boundary ... See full document

9

Design and Development of a Microscopic Electrical Impedance Tomography System

Design and Development of a Microscopic Electrical Impedance Tomography System

... electrodes, electrical instruments, and a PC with reconstruction algorithm ...device. Electrical instruments are devices that are used to transmit and receive the measurement from the ...the boundary ... See full document

5

New Solutions for the Three-Dimensional Electrical Impedance Equation and its Application to the Electrical Impedance Tomography Theory

New Solutions for the Three-Dimensional Electrical Impedance Equation and its Application to the Electrical Impedance Tomography Theory

... the boundary is a closed curve or a closed surface, the function u j could be represented using quite standard expansions, such as the Fourier ...the Electrical Impedance Tomography problem ... See full document

6

Adaptive mesh refinement techniques for electrical impedance tomography

Adaptive mesh refinement techniques for electrical impedance tomography

... Electrical impedance tomography (EIT) can provide images with well defined characteristics only when the full nonlinear reconstruction process is constrained by a property of the image such as its ... See full document

6

Electrical impedance tomography in acute respiratory distress syndrome

Electrical impedance tomography in acute respiratory distress syndrome

... finite element mesh, the images are projected into an array of 32 × 32 pixels, where each pixel will describe the resistivity variation over a time interval in relation to a ref- erence moment ... See full document

11

An Influence of the Noise on the Imaging Algorithm in the Electrical Impedance Tomography

An Influence of the Noise on the Imaging Algorithm in the Electrical Impedance Tomography

... the electrical current is injected according to the certain driven pattern, and the electrical potential of the body’s surface is measured by the ...injected electrical cur- rent is at a sufficiently ... See full document

5

Digital biomedical electrical impedance tomography based on FPGA

Digital biomedical electrical impedance tomography based on FPGA

... A digital biomedical electrical impedance tomogra- phy (EIT) system is developed with the aid of FPGA. The key elements of EIT system are described specif- ically in the paper. The functions are realized to ... See full document

5

Electrical Impedance Tomography using EIDORS in a Closed Phantom

Electrical Impedance Tomography using EIDORS in a Closed Phantom

... Finite Element Method is the basis for all the softwares used for reconstruction in EIT. EIDORS is used for 2-D and 3-D reconstruction of image based on voltage dataset. EIDORS is an open source suite implemented ... See full document

5

Recent progress on Frequency Difference Electrical Impedance Tomography

Recent progress on Frequency Difference Electrical Impedance Tomography

... Electrical Impedance Tomography(EIT) is a non-invasive imaging technique which aims to provide the cross- sectional distribution of electrical impedance inside the human ...the ... See full document

12

Electrical Impedance Based Spectroscopy and Tomography Techniques for Obesity and Heart Diseases

Electrical Impedance Based Spectroscopy and Tomography Techniques for Obesity and Heart Diseases

... inverse boundary value problem, formalized by the Caldéron's first paper on EIT of [58], presents a number of implications on the existence, uniqueness, and numerical stability of the solution ...full ... See full document

188

Optimization of the centre ground method of Electrical Impedance Tomography System

Optimization of the centre ground method of Electrical Impedance Tomography System

... Fig. 6. shows that at 5Khz better images for cucumber are obtained at all the three positions. At 10Khz and 15Khz cucumber gets detected only if it is kept either closer to the boundary or towards the centre ... See full document

7

A fast parallel solver for the forward problem in electrical impedance tomography

A fast parallel solver for the forward problem in electrical impedance tomography

... Borsic et al. [10] moved the forward and the Jacobian cal- culations (not the assembly of the system matrix, though) to sparse parallel direct solver library PARDISO [11] to surpass these limitations. They were able to ... See full document

13

Electrical impedance tomography system: an open access circuit design

Electrical impedance tomography system: an open access circuit design

... Here a brief overview of the system software is presented. According to the predefined tasks set by the system hard- ware design, different programs were developed. In the area of data acquisition, the developed software ... See full document

8

Electrical Impedance Tomography of human brain function

Electrical Impedance Tomography of human brain function

... This issue has been investigated by workers in EEG dipole modelling. Two approaches have been taken: analytical modelling o f the head as a series o f concentric spheres and, more recently, numerical modelling based on ... See full document

296

Modern Trends in Development of Electrical Impedance Tomography in Medicine

Modern Trends in Development of Electrical Impedance Tomography in Medicine

... finite element method and of nonlinear optimization; studying feasibility of using internal electrodes for improving accuracy; calibration of information and measurement systems; numerical interpolation methods; ... See full document

7

Finite element modelling and image reconstruction in single and multi frequency electrical impedance tomography

Finite element modelling and image reconstruction in single and multi frequency electrical impedance tomography

... f electrical im pedance tom ography (EIT) has been developing for som e years (Brown and B arber ...resulting boundary voltages are m easured as the differential voltages between two non-current carrying ... See full document

184

An Optimized Numerical Method for Solving the Two-Dimensional Impedance Equation

An Optimized Numerical Method for Solving the Two-Dimensional Impedance Equation

... Dirichlet boundary value problem, corresponding to the Impedance Equation in the plane, is an important contribution to the Electrical Impedance Tomography ...Finite Element ... See full document

6

Three Dimensional Electrical Impedance Tomography

Three Dimensional Electrical Impedance Tomography

... tetrahedral element is normalized by the sum of coefficients for the same drive/receive pair over all the ...circular boundary shape and accurate electrode positioning ... See full document

7

Application of natural and model experiment methodology in 
		two dimensional electrical impedance tomography

Application of natural and model experiment methodology in two dimensional electrical impedance tomography

... specific electrical conductance and the geometry of the anomalies based on the solution of an elliptic boundary value problem for the differential equation of the second order ... See full document

5

A Precision Transconductance for Electrical Impedance Tomography Using CMOS Technology

A Precision Transconductance for Electrical Impedance Tomography Using CMOS Technology

... Creating device with multiple threshold voltage is to apply different bias voltage to the base terminal of the transistor. In this circuit apply different bias voltage to the transistors. These circuits have large ... See full document

7

Show all 10000 documents...