• No results found

[PDF] Top 20 Detection of Epinephrine in Presence of Serotonin and Ascorbic Acid by TTAB Modified Carbon Paste Electrode: A Voltammetric Study

Has 10000 "Detection of Epinephrine in Presence of Serotonin and Ascorbic Acid by TTAB Modified Carbon Paste Electrode: A Voltammetric Study" found on our website. Below are the top 20 most common "Detection of Epinephrine in Presence of Serotonin and Ascorbic Acid by TTAB Modified Carbon Paste Electrode: A Voltammetric Study".

Detection of Epinephrine in Presence of Serotonin and Ascorbic Acid by TTAB Modified Carbon Paste Electrode: A Voltammetric Study

Detection of Epinephrine in Presence of Serotonin and Ascorbic Acid by TTAB Modified Carbon Paste Electrode: A Voltammetric Study

... conventional electrode (i.e., bare glassy carbon, graphite, Au, Pt) because of its high overpotential, electrode fouling property, poor reproducibility and poor ...of epinephrine sensor has ... See full document

19

Separation of Ascorbic Acid, Dopamine and Uric Acid by Acetone/Water Modified Carbon Paste Electrode: A Cyclic Voltammetric Study

Separation of Ascorbic Acid, Dopamine and Uric Acid by Acetone/Water Modified Carbon Paste Electrode: A Cyclic Voltammetric Study

... Acetone modified carbon paste electrode (20%:80%) has been shown to be effective for dopamine ...showed electrode process was diffusion ...in presence of AA and ... See full document

8

Simultaneous voltammetric measurement of ascorbic acid and dopamine at poly (vanillin) modified carbon paste electrode: A cyclic voltammetric study

Simultaneous voltammetric measurement of ascorbic acid and dopamine at poly (vanillin) modified carbon paste electrode: A cyclic voltammetric study

... the voltammetric signal of DA and AA. Only one broad voltammetric signal for DA and AA was observed at approximately 195 ...the electrode surface by the oxidation products results in a single ... See full document

9

Electrochemical Studies of Dopamine and Epinephrine at a Poly (Tannic Acid) Modified Carbon Paste Electrode: A Cyclic Voltammetric Study

Electrochemical Studies of Dopamine and Epinephrine at a Poly (Tannic Acid) Modified Carbon Paste Electrode: A Cyclic Voltammetric Study

... A carbon paste electrode (CPE) modified with poly (tannic acid) was used for the sensitive voltammetric determination of dopamine (DA) and epinephrine ...the ... See full document

10

Poly (Alanine) Modified Carbon Paste Electrode for Simultaneous Detection of Dopamine and Ascorbic Acid

Poly (Alanine) Modified Carbon Paste Electrode for Simultaneous Detection of Dopamine and Ascorbic Acid

... bare electrode for the voltammetric determination of DA in the presence of ...the voltammetric signal into two well defined voltammetric peaks at 41mV and 245mV corresponding to AA and ... See full document

10

Electrochemical Detection of Norepinephrine in the Presence of Epinephrine, Uric Acid and Ascorbic Acid Using a Graphene-modified Electrode

Electrochemical Detection of Norepinephrine in the Presence of Epinephrine, Uric Acid and Ascorbic Acid Using a Graphene-modified Electrode

... indicates that the redox reaction involves a transfer process of two protons. The effect of solution pH on the electrochemical signal is similar to the effect of solution pH on carbon-loated nickel magnetic ... See full document

10

Surfactant Induced Iron (II) Phthalocyanine Modified Carbon Paste Electrode for Simultaneous Detection of Ascorbic Acid, Dopamine And Uric Acid

Surfactant Induced Iron (II) Phthalocyanine Modified Carbon Paste Electrode for Simultaneous Detection of Ascorbic Acid, Dopamine And Uric Acid

... phthalocyanine modified carbon paste electrode (CTAB/Fe (II) ONTPc/CPE) was fabricated and was applied to simultaneous determination of ascorbic acid, dopamine and uric ...The ... See full document

10

Cyclic Voltammetric Investigation of Dopamine at p-aminobenzoic Acid Modified Carbon Paste Electrode

Cyclic Voltammetric Investigation of Dopamine at p-aminobenzoic Acid Modified Carbon Paste Electrode

... the detection of neurotransmitter in the extracellular fluid of the central nervous system as a received much interest in the past few decades ...coated carbon fibre microelectrodes as electrochemical ... See full document

10

Electrocatalytic Oxidation of Dopamine and Ascorbic Acid at Poly (Eriochrome Black-T) Modified Carbon Paste Electrode

Electrocatalytic Oxidation of Dopamine and Ascorbic Acid at Poly (Eriochrome Black-T) Modified Carbon Paste Electrode

... electrochemical detection of DA ...electrochemical detection of DA in real biological matrices is the coexistence of some interfering ...these ascorbic acid (AA) is of particular ...bare ... See full document

10

Cyclic Voltammetric Studies of Serotonin at Sodium Dodecyl Sulfate Modified Carbon Paste Electrode

Cyclic Voltammetric Studies of Serotonin at Sodium Dodecyl Sulfate Modified Carbon Paste Electrode

... the detection limits of some ...the presence of trace ...the electrode surface, which facilitated the electron or the substance transfer between the electrode and the ...sulphonic acid ... See full document

10

Selective Determination of Epinephrine in the Presence of Ascorbic Acid and Dopamine at Silver Doped Polyglycine Modified Electrode

Selective Determination of Epinephrine in the Presence of Ascorbic Acid and Dopamine at Silver Doped Polyglycine Modified Electrode

... as ascorbic acid (AA) and dopamine ...a modified electrode, which can eliminate to the EP determination [7, ...this study, a novel electrochemical sensor was fabricated with silver ... See full document

8

Resolution of Ascorbic Acid in The Presence of Uric Acid by The Montmorillonite K 10 -clay/SDS Modified Carbon Paste Electrode

Resolution of Ascorbic Acid in The Presence of Uric Acid by The Montmorillonite K 10 -clay/SDS Modified Carbon Paste Electrode

... present study involves the development of MMCPE/immobilized SDS modified carbon paste electrode by bulk modification (direct mixing) of carbon paste followed by ... See full document

8

Simultaneous Determination of Dopamine, Uric Acid and Ascorbic Acid with CTAB Modified Carbon Paste Electrode

Simultaneous Determination of Dopamine, Uric Acid and Ascorbic Acid with CTAB Modified Carbon Paste Electrode

... overlapping voltammetric response ...the electrode surface, which results in rather poor selectivity and sensitivity in addition, oxidation of DA at the electrode surface in the presence of AA ... See full document

10

Voltammetric Resolution of Dopamine in presence of Ascorbic Acid at Polyvinyl Alcohol Modified Carbon Paste Electrode

Voltammetric Resolution of Dopamine in presence of Ascorbic Acid at Polyvinyl Alcohol Modified Carbon Paste Electrode

... electrochemical detection of DA is serious interferences caused by the ascorbic acid (AA), L-Ascorbic acid (Vitamin C) (AA), a water soluble vitamin, is an extremely important substance ... See full document

10

Determination of Dopamine in presence of Ascorbic Acid at Eriochrome Black T Modified Carbon Paste Electrode : A Voltammetric Study

Determination of Dopamine in presence of Ascorbic Acid at Eriochrome Black T Modified Carbon Paste Electrode : A Voltammetric Study

... The electrode system contained a working carbon paste electrode, home made cavity of 3mm diameter, a platinum wire as counter electrode and saturated calomel electrode as ... See full document

9

Voltammetric Method for the Determination of Lactic Acid Using a Carbon Paste Electrode Modified with Cobalt Phthalocyanine

Voltammetric Method for the Determination of Lactic Acid Using a Carbon Paste Electrode Modified with Cobalt Phthalocyanine

... lactic acid sensor was fabricated by a carbon paste electrode (CPE) modified with cobalt phthalocyanine ...CoPC modified electrode in lactic acid solutions was ... See full document

7

Ferrocenedicarboxylic Acid Modified Multiwall Carbon Nanotubes Paste Electrode for Voltammetric Determination of Sulfite

Ferrocenedicarboxylic Acid Modified Multiwall Carbon Nanotubes Paste Electrode for Voltammetric Determination of Sulfite

... Cyclic voltammetry (CV), chronoamperommetry, and differential pulse voltammetry (DPV) were performed in an analytical system, Autolab with PGSTAT 12 (Eco Chemie B. V., Utrecht, and The Netherlands). The system was run on ... See full document

15

Electrocatlytic oxidation of ascorbic acid mediated by ZNO microcrystalline modified glassy carbon electrode

Electrocatlytic oxidation of ascorbic acid mediated by ZNO microcrystalline modified glassy carbon electrode

... The RDE technique was used to determine the diffusion coefficient and rate constant of ascorbic acid under specified condition. Figure 7 shows the oxidation of ascorbic acid at bare GC ... See full document

8

Electrochemical Determination of Vitamin A Based on a Novel Nanoalloy Modified Carbon Paste Electrode

Electrochemical Determination of Vitamin A Based on a Novel Nanoalloy Modified Carbon Paste Electrode

... This study proposed a new carbon paste electrode (CPE) that was modified using a nanoalloy (Pt:Co) room- temperature ionic liquid (RTIL) as an extremely sensitive sensor for the ... See full document

10

Voltammetric Behavior of a Modified Electrode With Azide Copper Octa(3-Aminopropyl)Octasilsesquioxane Composite in the Oxidation of Ascorbic Acid

Voltammetric Behavior of a Modified Electrode With Azide Copper Octa(3-Aminopropyl)Octasilsesquioxane Composite in the Oxidation of Ascorbic Acid

... [38] modified electrode the ASCA utility is not affected for high hidrogenionic concentration (pH < ...of ascorbic acid versus anodic current are shown in Figure ... See full document

14

Show all 10000 documents...