• No results found

[PDF] Top 20 Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography

Has 10000 "Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography" found on our website. Below are the top 20 most common "Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography".

Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography

Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography

... Fig. 3 shows the normalized permittivity, G where the values are in the range of 0 to 1, reconstructed by LBP, Landweber and GVSPM algorithms and compared to actual conditions for four cases. The number of iteration was ... See full document

5

Landweber iteration algorithm based on sensitivity updating strategy for electrical capacitance tomography

Landweber iteration algorithm based on sensitivity updating strategy for electrical capacitance tomography

... reconstructed image by some reconstruction algorithms, say, Landweber iterative ...iterative algorithm based on updated sensitivity matrix was presented in this ...reconstructed image based on ... See full document

7

Electrical Impedance Tomography Image Reconstruction Using Iterative Lavrentiev and L Curve Based Regularization Algorithm

Electrical Impedance Tomography Image Reconstruction Using Iterative Lavrentiev and L Curve Based Regularization Algorithm

... the electrical properties in the interior of a medium from measurements on its boundary, which is particularly important for medical and industrial applications ...curve-based algorithm to reconstruct EIT ... See full document

6

Segmented excitation for electrical capacitance tomography

Segmented excitation for electrical capacitance tomography

... Electrical Capacitance Tomography (ECT) system offers a non-invasive measurement for flow properties within ...project studies the performance of using segmented excitation of ECT system in ... See full document

27

Hardware development of electrical capacitance tomography for imaging a mixture of water and oil

Hardware development of electrical capacitance tomography for imaging a mixture of water and oil

... image reconstruction. These electrodes were connected directly to capacitance detection circuit through PCB ...Projection algorithm (LBP) for generating permittivity ... See full document

18

Modeling and Calibration of Electrical Capacitance Tomography Sensor for Medical Imaging

Modeling and Calibration of Electrical Capacitance Tomography Sensor for Medical Imaging

... of capacitance measured for 7 pairs of electrode excitation involving the electrodes 2 and 3 for normal bone and cracked bone are as shown in Fig ...of capacitance than the cracked ...the capacitance ... See full document

7

Performance Analysis of Grey Level Fitting Mechanism based Gompertz Function for Image Reconstruction Algorithms in Electrical Capacitance Tomography Measurement System

Performance Analysis of Grey Level Fitting Mechanism based Gompertz Function for Image Reconstruction Algorithms in Electrical Capacitance Tomography Measurement System

... Electrical capacitance tomography (ECT) is an industrial flow imaging technique which has been fast developed in recent ...measured capacitance and permittivity distribution , soft-field ... See full document

6

Dual modality tomography: the image analysis of forward problem

Dual modality tomography: the image analysis of forward problem

... process tomography which is the combination of dual modality; electrical capacitance and optical tomography for monitoring solid/gas flow ...Modality Tomography (DMT) system consists of ... See full document

12

A survey on real time electrical capacitance tomography using VLSI architecture

A survey on real time electrical capacitance tomography using VLSI architecture

... the reconstruction algorithm, without the need of series of sequential memory ...FPGA-based Electrical Impendence Tomography (EIT) system was disclosed in ...the image ... See full document

7

A review on electrical capacitance tomography sensor development

A review on electrical capacitance tomography sensor development

... the capacitance measures only charged /discharged once in a measurement ...cross-sectional image of the distribution electricity transparency to conduct measurement of a non-electric ...measured ... See full document

7

Towards 3D-Electrical Capacitance Tomography for Interface Detection164-175

Towards 3D-Electrical Capacitance Tomography for Interface Detection164-175

... the image was optimised by correlation with image ...calculating image error was compared with a volumetric approach demonstrating the robustness of the latter as it does not require precise ... See full document

12

A novel time-difference electrical impedance tomography algorithm using multi-frequency information

A novel time-difference electrical impedance tomography algorithm using multi-frequency information

... numerical simulation and the phantom experiment; however, the condition num- ber ...the reconstruction images under three-step iteration were not presented because they were ... See full document

23

Application of Gradient Projection for Sparse Reconstruction to Compressed Sensing for Image Reconstruction of Electrical Capacitance Tomography

Application of Gradient Projection for Sparse Reconstruction to Compressed Sensing for Image Reconstruction of Electrical Capacitance Tomography

... to image processing and image reconstruction as the sparsity is one of distinct characteristic of natural ...several image reconstruction algorithms for ECT based on CS were proposed, ... See full document

7

Inverse Problem: Comparison between Linear Back-Projection Algorithm and Filtered Back-Projection Algorithm in Soft-Field Tomography

Inverse Problem: Comparison between Linear Back-Projection Algorithm and Filtered Back-Projection Algorithm in Soft-Field Tomography

... FBP algorithm is used to sharpen the reconstructed image obtained from the LBP algorithm ...hard-field tomography Abstract: An image reconstruction algorithm in process ... See full document

5

An overview: effectiveness of different arrangement for electrode guard in electrical capacitance tomography

An overview: effectiveness of different arrangement for electrode guard in electrical capacitance tomography

... the capacitance changes between multiple of electrode sensors. The image is reconstructed base on the data collected via appropriate algorithm ...the capacitance at each of the receivers are ... See full document

7

Analytical image reconstruction methods in emission tomography

Analytical image reconstruction methods in emission tomography

... The reconstruction methods are divided into analytic and iterative approaches, each one presenting its own advantages and ...Analytic reconstruction methods offer a direct mathematical solution for the for- ... See full document

8

Finite element modelling and image reconstruction in single and multi frequency electrical impedance tomography

Finite element modelling and image reconstruction in single and multi frequency electrical impedance tomography

... age reconstruction algorithm , which showed som e success (Avis and B arber ...a reconstruction algorithm based on the inversion o f the sensitivity m atrix associated with a non-uniform ... See full document

184

Numerical Simulation Study on the  Detection of Weak Structural Plane  of Rock Slope by Using 3D Electrical  Resistivity Tomography

Numerical Simulation Study on the Detection of Weak Structural Plane of Rock Slope by Using 3D Electrical Resistivity Tomography

... 3D electrical resistivity tomography, a model of rock slope with weak structure plane is established, and the characteristics of three-dimen- sional resistivity imaging of weak structure plane under ... See full document

8

Developing Principles and Functioning Algorithms of the Hardware-software Complex for Electrical Impedance Tomography of Biological Objects

Developing Principles and Functioning Algorithms of the Hardware-software Complex for Electrical Impedance Tomography of Biological Objects

... etc., and electrical conductivity of the BO is reconstructed and visualized. There is a possibility to use for the research specialized software products [16,17,18] that implement the proposed ... See full document

10

Electrical impedance tomography based image reconstruction and feto maternal monitoring in pregnancy

Electrical impedance tomography based image reconstruction and feto maternal monitoring in pregnancy

... The electrical conductivity distribution was measured for a closed object using data acquisition methods. Data was collected by applying ac current pattern in the range of 1 - 5 mA at a frequency of 40 KHz to the ... See full document

5

Show all 10000 documents...