• No results found

active power distortion factor

Design and Simulation of Shunt Active Power Filter for Harmonic Compensation Using Fuzzy Logic Controller

Design and Simulation of Shunt Active Power Filter for Harmonic Compensation Using Fuzzy Logic Controller

... a power system. Harmonics cause distortion in current and voltage waveforms resulting into deterioration of the power ...in power system also has non-integer multiples of the fundamental ...

7

IMPROVED CONTROL METHOD OF GUPQC UNDER DISTORTED AND UNBALANCED LOAD CONDITION

IMPROVED CONTROL METHOD OF GUPQC UNDER DISTORTED AND UNBALANCED LOAD CONDITION

... - Power system load equipment, such as power electronic devices and microprocessor-based systems widely used in modern industries, it’s more sensitive to power quality variations than equipment ...

8

ABSTRACT Active power factor orrection technique can improve the input power factor and reduce the

ABSTRACT Active power factor orrection technique can improve the input power factor and reduce the

... phase power grid,With the rapid development of power electronic technology, more and more power electronic equipments are put into the power grid,Especially, the switching power supply ...

5

Harmonic Analysis and Its Mitigation Technique In Industrial Environment

Harmonic Analysis and Its Mitigation Technique In Industrial Environment

... filters, Active harmonic filters[7], [8] and Hybrid harmonic ...the power system by providing a high series impedance to block their flow, or a low-impedance parallel path is provided to divert the harmonic ...

6

High Power Factor Bridgeless SEPIC Converter to Improve Total Harmonic Distortion

High Power Factor Bridgeless SEPIC Converter to Improve Total Harmonic Distortion

... of power electronic devices has increased, which have an effect on the ...grid active power filter technique is ...bridgeless power factor correction circuit is ...

7

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

Average Current Mode Control Technique Applied To Boost Converter For Power Factor Improvement And Thd Reduction

... Power factor has a high impact on power system ...low power factor draws more current than a load with high power factor for the same amount of useful power ...low ...

9

Development of an AC DC boost power factor correction

Development of an AC DC boost power factor correction

... high power factor and total harmonic distortion in the current drawn from the ...of power quality [1], power factor corrector has been an active research topic in ...

34

A Novel Energy Management Software Using NI LabVIEW

A Novel Energy Management Software Using NI LabVIEW

... like power factor, active and reactive power, fundamental frequency, current and voltage frequency, energy components, harmonics and distortion ...the power factor ...

6

SEVEN LEVEL CONTROL OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENHANCEMENT

SEVEN LEVEL CONTROL OF SHUNT ACTIVE POWER FILTER FOR POWER QUALITY ENHANCEMENT

... Shunt Active Power Filter (SAPF) is one of the controllers to enhance power quality ...reactive power, improve the power factor and to suppress the total harmonic ...

10

A controlled current inverter for active distortion compensation and power factor correction

A controlled current inverter for active distortion compensation and power factor correction

... operating range for the active compensation system which is determined by the choice of average switching frequency hysteresis time and DC bus voltage of the inverter... The design of an[r] ...

6

Design of shunt active power filter to mitigate the harmonics caused by nonlinear loads

Design of shunt active power filter to mitigate the harmonics caused by nonlinear loads

... Harmonic distortion in a distribution system affects the system current and ...Harmonic distortion in cables affect by increasing the dielectric stress in the ...crest factor which represents the ...

42

Power Factor Correction of Three Phase Rectifier with Interleaved Boost Converter

Power Factor Correction of Three Phase Rectifier with Interleaved Boost Converter

... with Power Factor Correction (PFC) has been discussed in many papers ...high power applications. Power factor correction is becoming more important nowadays, as we are more concerned ...

6

Active Power Factor Correction for DC-DC Converter

Active Power Factor Correction for DC-DC Converter

... harmonic distortion in current waveform will lead to poor power ...Poor power factor increase the value RMS current, but the power delivered is ...improve power factor and ...

6

Residential Load Curve Analysis during Electric Vehicle Charging

Residential Load Curve Analysis during Electric Vehicle Charging

... the power quality of ...high power factor ...quality power standards. To evaluate the impact on power system, the data measured were inserted on a res- idential load curve of class B in ...

13

DEVELOPMENT OF BUCK-BOOST CONVERTER TO ACHIEVE HIGH PF USING SERIES RESONANT CIRCUIT - PART I

DEVELOPMENT OF BUCK-BOOST CONVERTER TO ACHIEVE HIGH PF USING SERIES RESONANT CIRCUIT - PART I

... improving power-converter performance in terms of size, efficiency, conducted electromagnetic emission and also transient ...high power potential, modularity and better ...

8

Optimal location of capacitor bank for power losses minimization

Optimal location of capacitor bank for power losses minimization

... The Active power (P), also known as working power, is the energy converted into useful ...Apparent power (S ), on the other hand, is the total energy consumed by a load or delivered by the ...

36

Reconfigurable Solar Converter: A Single-Stage Power Conversion Pv-Battery System

Reconfigurable Solar Converter: A Single-Stage Power Conversion Pv-Battery System

... the PV source is not available during the nights or during cloudy conditions. Wind energy may or may not be available. Other sources, such as fuel cells may be more reliable, but have monetary issues associated with ...

9

Power factor correction (PFC) of a single phase AC to DC Interleaved boost Converter by using novel control scheme

Power factor correction (PFC) of a single phase AC to DC Interleaved boost Converter by using novel control scheme

... [19] Zengshi Chen, Wenzhong Gao, Jiangang Hu, and Xiao Ye, ―Closed-Loop Analysis and Cascade Control of a Nonminimum Phase Boost Converter,‖ IEEE Trans. On Power Electronics, vol. 26, no. 4, pp. 1237-1252, April ...

6

Real Time Energy Monitoring for Single Phase System

Real Time Energy Monitoring for Single Phase System

... Potential Transformer is a voltage step down transformer which is used for the purpose of measurement of high value of voltage. These are connected across the line which is to be monitored. In addition these transformers ...

5

Investigation of Power Factor on Harmonic Effect due to Types of Voltage Source

Investigation of Power Factor on Harmonic Effect due to Types of Voltage Source

... The authors would like to express their gratitude to the Fundamental Research Grant Scheme (FRGS), School of Electrical System Engineering of Universiti Malaysia Perlis (UniMAP) and Power Electronics and ...

5

Show all 10000 documents...

Related subjects