synchrophasor data

Wide-Area Synchrophasor Data Server System and Data Analytics Platform

Wide-Area Synchrophasor Data Server System and Data Analytics Platform

... Synchrophasor data quality are affected by many ...quality data is GPS signal ...phasor data concentrator (PDC), the phasor time response can still be assembled ...

101

Survey on synchrophasor data quality and cybersecurity challenges, and evaluation of their interdependencies

Survey on synchrophasor data quality and cybersecurity challenges, and evaluation of their interdependencies

... of synchrophasor data has become increasingly ...standardized data management solutions for smart grid has only made this problem more ...streaming data subject to minimal processing owing to ...

20

From Available Synchrophasor Data to Short-Circuit Fault Identity: Formulation and Feasibility Analysis

From Available Synchrophasor Data to Short-Circuit Fault Identity: Formulation and Feasibility Analysis

... Abstract—This paper proposes a novel formulation for determining the short-circuit fault identity, that is the fault type, faulted line and exact fault distance on it, by using available synchrophasor ...

10

Early Anomaly Detection and Classification with Streaming Synchrophasor Data in Electric Energy Systems

Early Anomaly Detection and Classification with Streaming Synchrophasor Data in Electric Energy Systems

... a data-based analytical approach is of great need. Synchrophasor measurement, with the high sampling rate and the synchroniza- tion provided by GPS, becomes more and more attractive in monitoring and ...

127

Improving Reliability of Synchrophasor Data Gathering Method Using Network Coding Technique

Improving Reliability of Synchrophasor Data Gathering Method Using Network Coding Technique

... unavoidable. Data loss usually occurs in high traffic condition, collisions between simultaneous transmissions, or equipment ...malfunctions. Data loss also appears on the transmission link due to the ...

12

Review of approaches for using synchrophasor data for real-time wide-area control

Review of approaches for using synchrophasor data for real-time wide-area control

... Synchrophasor data must be robust to be trusted for use in real-time control and protection applications ...of synchrophasor measurements from PMUs, including timing accuracy, has also been a key ...

7

DFT-based Synchrophasor Estimation Algorithms and their Integration in Advanced Phasor Measurement Units for the Real-time Monitoring of Active Distribution Networks

DFT-based Synchrophasor Estimation Algorithms and their Integration in Advanced Phasor Measurement Units for the Real-time Monitoring of Active Distribution Networks

... stream data to a Phasor Data Concentrator (PDC), that processes them in order to identify and locate the fault with the minimum possible ...real-time synchrophasor-data with sufficient ...

183

Practical Challenges of Integrating Synchrophasor Applications into an EMS

Practical Challenges of Integrating Synchrophasor Applications into an EMS

... of Synchrophasor Data The massive data from PMUs has brought challenges to store, analyze and transmit results without causing a bottleneck in the available information processing ...of data, ...

6

Synchrophasors: Multilevel Assessment and Data Quality  Improvement for Enhanced System Reliability

Synchrophasors: Multilevel Assessment and Data Quality Improvement for Enhanced System Reliability

... of data (n<100) due to the high computational burden in finding the step direction, consequently its approach on the synchrophasor data blocks is not ...

152

Resilient Synchrophasor Networks for the Real-Time Monitoring, Protection and Control of Power Grids:from Theory to Validation

Resilient Synchrophasor Networks for the Real-Time Monitoring, Protection and Control of Power Grids:from Theory to Validation

... measured synchrophasor data latencies shown in ...measured synchrophasor data latency shows a bimodal distribution characterized by a mean value of 70 ms that, as expected, is higher than the ...

207

Online Detection of False Data Injection Attacks to Synchrophasor Measurements: A Data-Driven Approach

Online Detection of False Data Injection Attacks to Synchrophasor Measurements: A Data-Driven Approach

... purely data-driven approach is proposed for online detection of false data injection attacks for synchrophsor ...false synchrophasor data that is temporarily injected into a limited number of ...

10

Algorithms to Improve Performance of Wide Area Measurement Systems of Electric Power Systems

Algorithms to Improve Performance of Wide Area Measurement Systems of Electric Power Systems

... PMUs should have 10-20 frames/s reporting rate to get reporting rate 30-60 frames/s at receiving end. Performance of CS has been compared with ‘Fourier’, ‘cubic’, and ‘spline’ interpolation techniques. Results of ...

313

Pattern Mining and Anomaly Detection based on Power System Synchrophasor Measurements

Pattern Mining and Anomaly Detection based on Power System Synchrophasor Measurements

... We evaluated our detection framework on the actual Western Interconnection synchrophasor data. The raw PMU signals were down-sampled to 1Hz, so the time resolution for the MRA procedure was 1 second, and ...

7

Big data in power systems: a statistical approach on synchrophasor application

Big data in power systems: a statistical approach on synchrophasor application

... of data recovery is discussed using a singular value decomposition and matrix re-creation ...for data re-creation in this ...missing data is ...

38

Phasor measurement technology based power system monitoring and control

Phasor measurement technology based power system monitoring and control

... of synchrophasor data measurement, it is possible to establish the power system monitoring by directly employing spectral analysis of power or phase angle response signals use the Fourier Transforms or ...

6

Cyber Physical System Security — DoS Attacks on Synchrophasor Networks in the Smart Grid

Cyber Physical System Security — DoS Attacks on Synchrophasor Networks in the Smart Grid

... that data spoofing has very little effect when it is limited to a single data ...mitigate data spoofing the grid can use multiple PMUs to monitor the same electrical transmission bus or line, which ...

153

Space Vector Taylor-Fourier Models for Synchrophasor, Frequency, and ROCOF Measurements in Three-Phase Systems

Space Vector Taylor-Fourier Models for Synchrophasor, Frequency, and ROCOF Measurements in Three-Phase Systems

... redundant data is returned by (24), since, when looking at the SV, it is a linear, holomorphic function of the positive and the conjugate of the negative sequence ...sequence synchrophasor: in this way it ...

15

Effect of Unbalance on Positive-Sequence Synchrophasor, Frequency and ROCOF Estimations

Effect of Unbalance on Positive-Sequence Synchrophasor, Frequency and ROCOF Estimations

... The theoretical analysis indicates that the influence of unbalance is radically different for each algorithm, depending on its capability to reject the equivalent harmonic disturbance. All the methods relying on a ...

11

Smart Energy Systems: using IoT Embedded Architectures for Implementing a Computationally Efficient Synchrophasor Estimator

Smart Energy Systems: using IoT Embedded Architectures for Implementing a Computationally Efficient Synchrophasor Estimator

... • PLC modems. They have usually a proprietary architecture, that depends on design choices and specific implementations. Nevertheless, some ele- ments are in common, as the input coupling section. This is usually imple- ...

173

Locating Faults on Untransposed, Meshed Transmission Networks Using a Limited Number of Synchrophasor Measurements

Locating Faults on Untransposed, Meshed Transmission Networks Using a Limited Number of Synchrophasor Measurements

... PMU data and give rise to almost the same accurate ...bad data detection can be readily deployed in these methods to achieve the highest possible ...

12