Experimental Study on Flow Characteristic in Sloping Weir
... Diversion weir is one of the most frequently installed riparian ...diversion weir is comprised of a main body, an apron and a bed pitching and the related design standards are suggested in River Design ... See full document
9
Experimental Study on Heat Transfer and Flow Characteristics of Air Cooling through Cross-flow Microchannel Heat Exchanger
... An experimental study was performed to characterize air-side heat transfer and fluid flow behaviors via cross-flow microchannel heat exchangers during air ...mass flow rates of ... See full document
136
Experimental Study of Flow Characteristic at Horizontal Mini Channel
... the experimental apparatus used in the present ...their flow rates are measured individually by flow ...two-phase flow took place and a lightening system put at bottom test ...data flow ... See full document
6
Study Of Flow Characteristics Of Contracted Sharp Crested Rectangular Weir
... an experimental study has been carried out in a rectangular channel of dimensions ...rectangular weir, by varying the weir width (b) and the weir height ...each weir width, ... See full document
7
A Study of The Turbulent Flows in Sloping and Adversely Sloping Rectangular Culvert
... an experimental investigation was carried out to study the turbulent flows and flow characteristics through sloping and adve rsely sloping rectangular culvert in rectangular channel of ... See full document
15
Evaluation of unsteady open channel flow characteristics over a crump weir
... This study will focus on identifying the characteristics of flow and to obtain the profile of water flow over a crump ...Crump weir in the rectangular open channel model will be used to ... See full document
10
Investigation of Discharge Behaviour From a Sharp-Edged Circular Orifice in Both Weir and Orifice Flow Regimes Using an Unsteady Experimental Procedure
... the weir flow regime. The experimental exponent in the weir flow regime does not mimic the theoretical exponent and thus true weir flow has not been ...the weir ... See full document
73
An experimental study of regime transitions in a differentially heated baroclinic annulus with flat and sloping bottom topographies
... to study the onset of baroclinic instability, using horizontal and uniformly sloping bottom ...wave flow regimes have been identified and their phase boundaries – expressed in terms of appropriate ... See full document
14
Twin Plate Weir: A Flow Measuring Device (TECHNICAL NOTE)
... small flow discharges in open channels. Experimental data available in the literature are added, to study the effect of the slit ...to study twin plate weir for open channels in ... See full document
8
Analysis on River Bed Changes in Weir Downstream by Real Scale Experiment
... a weir downstream part according to the change in river bed slopes through the conventional small weir model experiment ...our study, the model scale effect must be ...this study investigated ... See full document
9
Experimental Study on Heat Sink Using Screw Thread
... Samudrala Mohan Venkatesh et al [3] Fins improve the heat transfer rate through the surface by increasing the exposed area. In this study a threaded pin fin is analyzed numerically. A cylindrical pin fin is ... See full document
9
New Stilling Basins Designs for Deep Rectangular Outlets
... The experimental study reported here is intended to evolve new designs of stilling basins for deep and narrow openings used as ...wall, weir wall, sloping end sill and wedge shaped blocks are ... See full document
10
Experimental Study of Hydrograph Model of Catchment Area Based on Regional Characteristic
... The symplification of hydrology cycle elements conceptuals is a basic principle that will be developed as a volume calculation or water flow from the all flow components that maybe occur in one area or ... See full document
6
An Experimental Study with Tensor Flow for Characteristic mining of Mathematical Formulae from a Document
... The overall Sensitivity Measure with Tensorflow model is presented in tables 7-9 and from the tables it is obvious that with huge training data more number of matched math formulae f[r] ... See full document
10
An Experimental Study on the Dissipation Effect of a Baffle Downstream of a Weir
... good flow dissipation effect. The square baffle had large flow dissipation due to a large flow block effect because its flow blocking area was relatively larger than those of other ...upstream ... See full document
13
Experimental Study for the Determination of the Material Diameter of the Riprap Bed Protection
... a study on the riprap diameter of a strong turbulence area around the downstream of hydraulic ...This study was an experimental study for deciding the riprap diameter installed around apron ... See full document
10
DEPENDABLE FLOW ANALYSIS IN LEMATANG WEIR
... to study the characteristics of weather and climate in an area for the benefit of water resource management and its utilization for the welfare of the community ...and study rainfall in the tropics area in ... See full document
5
An experimental and theoretical investigation of side weirs
... The first stage of the project was to construct a flume capable of side weir experimentation as the university does not have anything suitable. Preliminary thoughts on the matter involved connecting a flume onto ... See full document
129
Assessment of Characteristic Strength of M30 Grade Concrete Using Soil as a Partial Replacement of Sand
... this study complied with the Egyptian code requirement for structural bricks, with granite slurry having a positive effect on cement brick samples that reached its optimum at 10 per cent slurry ... See full document
8
An Experimental Study on the Temperature Characteristic of a 940 nm Semiconductor Laser Diode
... present study investigates the impact of tempera- ture on the P-I curve, V-I curve and the centre wavelength, the temperature ranging from ...the characteristic temperature is calculated to be 120 ... See full document
8
Related subjects