• No results found

[PDF] Top 20 Research on Performance of Ground Source Heat Pump Double U Underground Pipe Heat Exchange

Has 10000 "Research on Performance of Ground Source Heat Pump Double U Underground Pipe Heat Exchange" found on our website. Below are the top 20 most common "Research on Performance of Ground Source Heat Pump Double U Underground Pipe Heat Exchange".

Research on Performance of Ground Source Heat Pump Double U Underground Pipe Heat Exchange

Research on Performance of Ground Source Heat Pump Double U Underground Pipe Heat Exchange

... depth heat exchange in the single U pipe and the double U pipe as ...depth heat exchange between single U pipe and double U ... See full document

6

An experimental study on influence of surface corrugations to heat transfer using double pipe heat exchanger

An experimental study on influence of surface corrugations to heat transfer using double pipe heat exchanger

... of heat transfer In contrast to the augmentation in the heat transfer rate, the heat transfer enhancement technique also escalates largely the friction factor and the required pumping power in the ... See full document

5

Numerical Study of Corrugation on Performance of Double Pipe Heat Exchanger

Numerical Study of Corrugation on Performance of Double Pipe Heat Exchanger

... Double pipe heat exchanger (DPHE) or concentric tube heat exchanger is one of the most simple and applicable heat ...of heat exchanger is widely used in chemical, food, oil and ... See full document

13

Experiments Using  Capillary Mat as Ground Heat  Exchanger for Ground Source  Heat Pump Heating Application

Experiments Using Capillary Mat as Ground Heat Exchanger for Ground Source Heat Pump Heating Application

... demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating ...of ground coupled heat ...the heat exchangers can be ... See full document

16

PLANT GROWTH MODELING OF ZINNIA ELEGANS JACQ USING FUZZY MAMDANI AND L SYSTEM 
APPROACH WITH MATHEMATICA

PLANT GROWTH MODELING OF ZINNIA ELEGANS JACQ USING FUZZY MAMDANI AND L SYSTEM APPROACH WITH MATHEMATICA

... Ground source heat pump system employs a great variety of antifreeze solutions, including water, sodium chloride, calcium chloride, methanol, ethanol, ethylene glycol, potassium acetate, ... See full document

7

EXPERIMENTAL COOLER BOX PERFORMANCE USING TWO DIFFERENT HEAT REMOVAL UNITS: A HEAT SINK FIN-FAN, AND A DOUBLE FAN HEAT PIPE

EXPERIMENTAL COOLER BOX PERFORMANCE USING TWO DIFFERENT HEAT REMOVAL UNITS: A HEAT SINK FIN-FAN, AND A DOUBLE FAN HEAT PIPE

... the performance of the cooler box is difficult due to low COP (coefficient of performance) of the thermoelectric module ...the performance of TE by discovering new materials, ...the ... See full document

7

Numerical Investigation of Heat Performance Enhancement for a Double Pipe Heat Exchanger at Annulus with Continuous Helical Baffles using Al2O3 as Nanofluid

Numerical Investigation of Heat Performance Enhancement for a Double Pipe Heat Exchanger at Annulus with Continuous Helical Baffles using Al2O3 as Nanofluid

... paper research is done on those types of heat exchangers that are used in small machinery with low pumping ...increasing heat transfer and neglecting pressure ...thermal performance ... See full document

13

Study and Experimental Analysis of Horizontal Ground Source Heat Pump System

Study and Experimental Analysis of Horizontal Ground Source Heat Pump System

... the performance of GSHP system of heating mode for the climatic conditions of Sindri, ...his research we have been discovered many operating and designing parameters, but still there are mamy other issues ... See full document

9

Parametric Study of Vertical Ground Loop Heat Exchangers for Ground Source Heat Pump Systems

Parametric Study of Vertical Ground Loop Heat Exchangers for Ground Source Heat Pump Systems

... the heat transfer process in VGLHEs, there is a scarcity of detailed parametric investigation of ...present research undertook an extensive CFD parametric investigation to compare and evaluate the ... See full document

122

“OPTIMIZATION OF GROUND SOURCE HEAT PUMP:A REVIEW”

“OPTIMIZATION OF GROUND SOURCE HEAT PUMP:A REVIEW”

... latest research on energy piles demonstrates that most scholars are focusing their attention on optimization by designing more efficient heat exchanger coils, analyzing the heat pump matching ... See full document

9

DESIGN DEVELOPMENT & ANALYSIS OF HYBRID AIR-CONDITIONER

DESIGN DEVELOPMENT & ANALYSIS OF HYBRID AIR-CONDITIONER

... a heat pipe heat exchanger to dehumidification enhancement in tropical HVAC systems a baseline performance characteristics study, the author had established the baseline performance ... See full document

5

An Approach for Combining of Solar Heating System with Ground Source Heat Pump System

An Approach for Combining of Solar Heating System with Ground Source Heat Pump System

... this research is to evaluate the environmental impacts of the energy and material used in the implementation of the serial SHP and to identify areas for improvement through the application of the ... See full document

10

Numerical Optimization of Double Tube GHE for Ground Source Heat Pump

Numerical Optimization of Double Tube GHE for Ground Source Heat Pump

... GHE performance analysis which helps to improve the thermal performance and economic efficiency of GSHP and GHE ...BHE’s performance. To maximize the thermal performance and minimize the cost, ... See full document

12

Mathematical model for optimising the performance of a ground source heat pump

Mathematical model for optimising the performance of a ground source heat pump

... The ground heat exchanger is the closed vertical type (U-shaped) and generally has 24-30 boreholes of depth ranging from 50- 175 m in depth depending on the load ...the ground located at ... See full document

150

Performance Investigation of Multiple-Tube Ground Heat Exchangers for Ground-Source Heat Pump

Performance Investigation of Multiple-Tube Ground Heat Exchangers for Ground-Source Heat Pump

... the ground and used as boreholes for the GHEs. Multiple-tube GHEs including U-tube, multi-tube, three-tube, four-tube types where a number of pipes installed inside the boreholes at 20 m depth were ... See full document

5

A performance comparison between an air-source and a ground-source reversible heat pump

A performance comparison between an air-source and a ground-source reversible heat pump

... the performance of a reversible ground-source heat pump, coupled to a municipality water reticulation system, is compared experimentally and with simulations to a conventional ... See full document

8

Heat Transer and Exergy Analysis of A Double Pipe Heat Exchanger

Heat Transer and Exergy Analysis of A Double Pipe Heat Exchanger

... Abstract- Heat exchangers are the important engineering systems with wide variety of applications including power plants, nuclear reactors, refrigeration and air-conditioning systems, heat recovery systems, ... See full document

7

Heat Transfer Enhancement in Double Pipe Heat Exchanger with Twisted Type Inserts In ANSYS Fluent

Heat Transfer Enhancement in Double Pipe Heat Exchanger with Twisted Type Inserts In ANSYS Fluent

... the heat transfer rate, some kind of insert is placed in the flow passages and they also reduce the hydraulic diameter of the flow ...passages. Heat transfer enhancement in a tube flow is due to flow ... See full document

5

Study on Waste Heat Resource Utilization System for a Mine

Study on Waste Heat Resource Utilization System for a Mine

... system is 25,000 GJ, and the waste heat utilization system consumes 791 thousand and 800 degrees. According to China's coal and electricity conversion standard which 1 degree of electricity consume 0.298 kilogram ... See full document

6

On the applicability of the moving line source theory to thermal response test under groundwater flow: considerations from real case studies

On the applicability of the moving line source theory to thermal response test under groundwater flow: considerations from real case studies

... When ground layers are saturated and significant groundwater flow occurs, the standard interpretation of the TRT, based on the assumption of pure conduction in the ground, fails and it becomes impossible to ... See full document

17

Show all 10000 documents...

Related subjects