• No results found

[PDF] Top 20 Comparing Shape and Image Reconstruction in Electrical Capacitance Tomography

Has 10000 "Comparing Shape and Image Reconstruction in Electrical Capacitance Tomography" found on our website. Below are the top 20 most common "Comparing Shape and Image Reconstruction in Electrical Capacitance Tomography".

Comparing Shape and Image Reconstruction in Electrical Capacitance Tomography

Comparing Shape and Image Reconstruction in Electrical Capacitance Tomography

... number, shape, size and, perhaps, contrast of a collection of anomalous ...permittivity reconstruction is reformu- lated to a special geometrical representation of the ...ECT reconstruction is ... See full document

6

Performance Analysis of Grey Level Fitting Mechanism based Gompertz Function for Image Reconstruction Algorithms in Electrical Capacitance Tomography Measurement System

Performance Analysis of Grey Level Fitting Mechanism based Gompertz Function for Image Reconstruction Algorithms in Electrical Capacitance Tomography Measurement System

... Electrical capacitance tomography (ECT) is an industrial flow imaging technique which has been fast developed in recent ...measured capacitance and permittivity distribution , soft-field ... See full document

6

Application of Gradient Projection for Sparse Reconstruction to Compressed Sensing for Image Reconstruction of Electrical Capacitance Tomography

Application of Gradient Projection for Sparse Reconstruction to Compressed Sensing for Image Reconstruction of Electrical Capacitance Tomography

... spare reconstruction (CS-GPSR) is applied to electrical capacitance tomography (ECT) image reconstruction in this ...the capacitance measurements and corresponding ... See full document

7

Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography

Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography

... iterative image reconstructions have been applied to solve the ill-posed inverse problem on electrical capacitance tomography for gas-solid two- phase flow namely LBP, Landweber and ...the ... See full document

5

Landweber iteration algorithm based on sensitivity updating strategy for electrical capacitance tomography

Landweber iteration algorithm based on sensitivity updating strategy for electrical capacitance tomography

... Electrical capacitance tomography (ECT) is one kind of process tomography techniques which was developed during the late 1980s [1, ...of image reconstruction for ECT is to ... See full document

7

Segmented excitation for electrical capacitance tomography

Segmented excitation for electrical capacitance tomography

... For ECT, the common installation of sensor is mounted outside the pipe [19, 20]. The sensors do not directly contact with the materials inside the pipe. ECT is a non-invasive and non-intrusive measurement technique. ... See full document

27

Modeling and Calibration of Electrical Capacitance Tomography Sensor for Medical Imaging

Modeling and Calibration of Electrical Capacitance Tomography Sensor for Medical Imaging

... are capacitance values proportional to the permittivity change ...and capacitance variation which changes with change in permittivity, it is concluded that such a sensor can be a suitable option for bone ... See full document

7

Hardware development of electrical capacitance tomography for imaging a mixture of water and oil

Hardware development of electrical capacitance tomography for imaging a mixture of water and oil

... Twelve electrodes ECT sensor was constructed, as this number will produce better and adequate data for image reconstruction. These electrodes were connected directly to capacitance detection circuit ... See full document

18

A Grey Level Fitting Mechanism based on Gompertz Function for Two Phase Flow Imaging using Electrical Capacitance Tomography Measurement Systems

A Grey Level Fitting Mechanism based on Gompertz Function for Two Phase Flow Imaging using Electrical Capacitance Tomography Measurement Systems

... popular image reconstruction algorithm is called the Linear Back Projection (LBP) ...of image from LBP reconstructing algorithm, fitting of normalized capacitance measurement data is often ... See full document

6

Modeling and Implementation of AC Electrical Capacitance Tomography

Modeling and Implementation of AC Electrical Capacitance Tomography

... inter-electrodes capacitance by applying multiple excitation signals [10], the CMOS circuit design of capacitance sensor for detecting changes of capacitance due to the incidence of particles or ... See full document

14

Mobile electrical capacitance tomography (ECT) development for liquid gas flow measurement

Mobile electrical capacitance tomography (ECT) development for liquid gas flow measurement

... Process Tomography is a technique of obtaining images of a cross section of an industrial process, for example, a multi-phase flow in an oil pipeline, so that the internal behavior can be investigated ...Process ... See full document

5

A survey on real time electrical capacitance tomography using VLSI architecture

A survey on real time electrical capacitance tomography using VLSI architecture

... the reconstruction algorithm, without the need of series of sequential memory ...FPGA-based Electrical Impendence Tomography (EIT) system was disclosed in ...the image reconstruction ... See full document

7

A review on electrical capacitance tomography sensor development

A review on electrical capacitance tomography sensor development

... the capacitance measures only charged /discharged once in a measurement ...cross-sectional image of the distribution electricity transparency to conduct measurement of a non-electric ...measured ... See full document

7

Towards 3D-Electrical Capacitance Tomography for Interface Detection164-175

Towards 3D-Electrical Capacitance Tomography for Interface Detection164-175

... Gauss-Newton reconstruction algorithm was used, another approach that is not yet commercially available and is largely confi ned to academia, yielding an image error of approximately 10% although this ... See full document

12

Dual modality tomography: the image analysis of forward problem

Dual modality tomography: the image analysis of forward problem

... process tomography which is the combination of dual modality; electrical capacitance and optical tomography for monitoring solid/gas flow ...Modality Tomography (DMT) system consists of ... See full document

12

Electrical Capacitance Volume Tomography Validation of Column Flotation Process with Gas Injection Variation

Electrical Capacitance Volume Tomography Validation of Column Flotation Process with Gas Injection Variation

... size, shape and colour of the bubbles, whereas dynamic monitoring perceives the size distribution, number, rate and stability of the ...x-y). Image analysis of the processes can describe the properties of ... See full document

13

Electrical Capacitance Volume Tomography: a Comparison Between 12- and 24-Channels Sensor Systems

Electrical Capacitance Volume Tomography: a Comparison Between 12- and 24-Channels Sensor Systems

... (3) image reconstruction algorithms. In capacitance tomography, most of the efforts to enhance image resolution have been by far focused on the third component ...state-of-the-art ... See full document

12

Optimal imaging with adaptive mesh refinement in electrical tomography

Optimal imaging with adaptive mesh refinement in electrical tomography

... of reconstruction error. A direct method for comparing two images is to take the norm of the difference of conductivities at sample points across the ...are comparing images reconstructed on ... See full document

8

Electromagnetic inductance tomography (EMT): sensor, electronics and image reconstruction for a system with a rotatable parallel excitation

Electromagnetic inductance tomography (EMT): sensor, electronics and image reconstruction for a system with a rotatable parallel excitation

... The development of EMT together with ECT and ERT provide three fundamental electrical tomography techniques based on the measurement of resistance, capacitance and now inductance; collec[r] ... See full document

6

Computed Tomography Image Reconstruction in 3D VoxelSpace

Computed Tomography Image Reconstruction in 3D VoxelSpace

... The standard terms of pixels and voxels are widely used to represent the basicmeasurements of a picture. Pixels were defined as an element that has two dimensions, the horizontal dimension representing the element’s ... See full document

8

Show all 10000 documents...