• No results found

interconnected reheat thermal system

LOAD FREQUENCY CONTROL OF FOUR AREA POWER SYSTEM USING ARTIFICIAL INTELLIGENCE

LOAD FREQUENCY CONTROL OF FOUR AREA POWER SYSTEM USING ARTIFICIAL INTELLIGENCE

... The dynamic responses are found to be deteriorating. In the next part of the work, the conventional integral controller is replaced by the fuzzy logic controller (FLC) and the dynamic responses are observed after ...

11

Adaptive Fuzzy Control Approach For Automatic Generation Control Of Two-Area Interconnected Hydro-Thermal System

Adaptive Fuzzy Control Approach For Automatic Generation Control Of Two-Area Interconnected Hydro-Thermal System

... two-area interconnected power system taken as a test system in this study consists of reheat turbine type thermal unit as area-1and hydro unit as area-2 ...power system is as ...

6

AUTOMATIC GENERATION CONTROL OF TWO AREA POWER SYSTEM WITH AND WITHOUT SMES: FROM CONVENTIONAL TO MODERN AND INTELLIGENT CONTROL

AUTOMATIC GENERATION CONTROL OF TWO AREA POWER SYSTEM WITH AND WITHOUT SMES: FROM CONVENTIONAL TO MODERN AND INTELLIGENT CONTROL

... The system investigated for LFC in this study is a two area interconnected power system with reheat turbine type thermal unit in each ...an interconnected power system, a ...

15

Automatic Generation Control for an Interconnected Reheat Thermal Power Systems Using Wavelet Neural Network Controller

Automatic Generation Control for an Interconnected Reheat Thermal Power Systems Using Wavelet Neural Network Controller

... I.A.Chidambaram (1966) received Bachelor of Engineering in Electrical and Electronics Engineering (1987), Master of Engineering in Power System Engineering (1992) and PhD in Electrical Engineering (2007) from ...

8

LFC in hydro thermal System Using Conventional and Fuzzy Logic Controller

LFC in hydro thermal System Using Conventional and Fuzzy Logic Controller

... In interconnected power system, small load perturbation in any of the area causes the fluctuation of the frequency of each and every area and also there is fluctuation of power in tie ...an ...

7

Evaluation of Power System Restoration 
		Indices using Krill Herd algorithm based optimized PI+ controller for a 
		restructured power system with facts devices

Evaluation of Power System Restoration Indices using Krill Herd algorithm based optimized PI+ controller for a restructured power system with facts devices

... Power System Restoration (PSR) Indices based on the Automatic Generation Control (AGC) assessment of two-area thermal reheat power system with FACTS devices in a restructured ...power ...

17

Attitude towards E-learning Technology -- A study in Kerala

Attitude towards E-learning Technology -- A study in Kerala

... two-area interconnected power systems when subjected to Time constant parametric ...Power system model consists of one area with reheat thermal power plants and other area with hydro power ...

20

Control Performance Standard based Load Frequency Control of a two area Reheat Interconnected Power System considering Governor Dead Band nonlinearity using Fuzzy Neural Network

Control Performance Standard based Load Frequency Control of a two area Reheat Interconnected Power System considering Governor Dead Band nonlinearity using Fuzzy Neural Network

... of reheat interconnected two area power systems are mainly characterized by non-linearity and ...of system. The system was simulated and the output responses of frequency deviations in area 1 ...

8

An Effect of Biogeography Based Optimization based frequency stabilizer on Load Frequency Control of an Interconnected Hydro-Thermal Power System

An Effect of Biogeography Based Optimization based frequency stabilizer on Load Frequency Control of an Interconnected Hydro-Thermal Power System

... an interconnected two-area hydro-thermal power system. Thermal unit is equipped with single-stage reheat turbine and hydro unit is studied with electrical ...

10

Improving The Dynamic Performance Of Interconnected Three Area Power System Using I, Pi & Fuzzy Controllers

Improving The Dynamic Performance Of Interconnected Three Area Power System Using I, Pi & Fuzzy Controllers

... This paper present analysis on dynamic performance of Load Frequency Control (LFC) of three area interconnected thermal reheat power system by the use of I, PI & Fuzzy Controller. The ...

6

Multi Area Thermal System with Automatic Generation Control for Fuzzy Logic Controller using TCPS-SMES

Multi Area Thermal System with Automatic Generation Control for Fuzzy Logic Controller using TCPS-SMES

... an interconnected thermal-thermal system ...an interconnected power system with AGC comprises two control ...two reheat thermal power generation units and Area 2 ...

5

II. FOPID CONTROLLERS:

II. FOPID CONTROLLERS:

... multi-area interconnected Power system with unequal reheat thermal ...area thermal system and compared with PSO FOPID ...enhancing system dynamic ...

6

Ant Lion Optimization Based Controller Tuning for Automatic Generation Control of Multiarea Interconnected Thermal System

Ant Lion Optimization Based Controller Tuning for Automatic Generation Control of Multiarea Interconnected Thermal System

... the system is dependent on the active power supply of the system according to the load ...non-reheat thermal system using Ant Lion optimization (ALO) ...

7

Two-Layer Fuzzy Logic Based Load-Frequency Controller for a Two-Area Interconnected Power System Considering Nonlinearities with Super Capacitor Energy Storage Units V. Adhimoorthy 1, Dr.I.A. Chidambaram2

Two-Layer Fuzzy Logic Based Load-Frequency Controller for a Two-Area Interconnected Power System Considering Nonlinearities with Super Capacitor Energy Storage Units V. Adhimoorthy 1, Dr.I.A. Chidambaram2

... storage system in addition to the kinetic energy of the generator rotors provides adequate control to damp out the frequency ...the interconnected system due to the economical ...two-area ...

13

Power System Restoration Assessment Indices computation for a Restructured Power System with Bacterial Foraging Optimized Load   Frequency Controller

Power System Restoration Assessment Indices computation for a Restructured Power System with Bacterial Foraging Optimized Load Frequency Controller

... Power System Restoration Assessment Indices (PSRAI) for a Two-Area Hydro-Thermal Reheat Interconnected Power System (TAHTRIPS) in a restructured environment with a load- frequency ...

14

Two Area Load Frequency Control Using DE Tuned PID Controller with Nonlinearity

Two Area Load Frequency Control Using DE Tuned PID Controller with Nonlinearity

... non reheat thermal interconnected system is carried out in MATLAB/SIMULINK under different ...the system parameters by 50% (either increasing it or decreasing the particular parameter) ...

9

Load Frequency Control of Interconnected Hydro-Thermal Power System Using Conventional PI and Fuzzy Logic Controller

Load Frequency Control of Interconnected Hydro-Thermal Power System Using Conventional PI and Fuzzy Logic Controller

... Conventional Proportional plus Integral controller (PI) provides zero steady state frequency deviation, but it exhibits poor dynamic performance (such as number of oscillation and more settling time), especially in the ...

6

Application of Group Hunting Search Optimized Cascade PD-Fractional Order PID Controller in Interconnected Thermal Power System

Application of Group Hunting Search Optimized Cascade PD-Fractional Order PID Controller in Interconnected Thermal Power System

... The purpose of this paper is to validate the performance of cascade PD-FOPID controller optimized by GHS algorithm as an improved secondary controller of the interconnected thermal power system by ...

12

Design and Analysis of Material for the Pipeline between Power Plant Accessories

Design and Analysis of Material for the Pipeline between Power Plant Accessories

... A thermal power station or a coal fired thermal power plant is by far, the most conventional method of generating electric power with reasonably high ...

11

 AN EFFICIENT INFORMATION RETRIEVAL SYSTEM USING QUERY EXPANSION AND 
DOCUMENT RANKING

 AN EFFICIENT INFORMATION RETRIEVAL SYSTEM USING QUERY EXPANSION AND DOCUMENT RANKING

... power system is proposed using Artificial Cooperative Search ...the thermal power system for optimal transient performance in deregulated ...deregulated thermal power system under ...

10

Show all 10000 documents...

Related subjects