• No results found

[PDF] Top 20 ANFIS Tuning for Optimization of Two Area Automatic Generation Control Power System

Has 10000 "ANFIS Tuning for Optimization of Two Area Automatic Generation Control Power System" found on our website. Below are the top 20 most common "ANFIS Tuning for Optimization of Two Area Automatic Generation Control Power System".

ANFIS Tuning for Optimization of Two Area Automatic Generation Control Power System

ANFIS Tuning for Optimization of Two Area Automatic Generation Control Power System

... with ANFIS algorithm proposed to improves trajectory tracking performance of two area power ...of ANFIS tuned system compare with conventional PID shows good quality ... See full document

9

Improving Automatic Generation Control a Two-Area Power System Using FOPID with Harmony Search Algorithm

Improving Automatic Generation Control a Two-Area Power System Using FOPID with Harmony Search Algorithm

... of automatic generation control in an interconnected two-area non- linear power system is ...developed optimization algorithm called HSA is implemented for ... See full document

7

Automatic Generation Control of Two Area Linear & Non Linear System using Teaching Learning Optimization Technique

Automatic Generation Control of Two Area Linear & Non Linear System using Teaching Learning Optimization Technique

... performs two stages, first tested to a linear two-area power system model and then continued to a non-linear power system model by as the effect of governor dead band ... See full document

10

Generation Optimization Using Two Area Control

Generation Optimization Using Two Area Control

... output power of various generators at different power plants in an electric power system, in response to change in load, a system called as Automatic generation controlled ... See full document

6

AGC of Multi Source Multi Area Power System using ADRC

AGC of Multi Source Multi Area Power System using ADRC

... the generation and the load demand causes the change in system frequency from its nominal ...the system nominal ...interconnected power system. The tuning of PID controller as a ... See full document

12

Automatic Generation Control in Three-Area Power System Operation by using “Particle Swarm Optimization Technique”

Automatic Generation Control in Three-Area Power System Operation by using “Particle Swarm Optimization Technique”

... Three unequal area (area 1: 2000 MW, area 2: 4000 MW, and area 3: 8000 MW) are considered. The systems are provided with single reheat turbines, integral controllers. The nominal parameters of ... See full document

8

Automatic Generation Control of Multi Area Power System A ANN Approach

Automatic Generation Control of Multi Area Power System A ANN Approach

... and two research papers in IEEE Conferences. His research interests‟ area includes Intelligent Techniques, Optimization Technique, Control System, Signal Processin, Measurement and ... See full document

5

AUTOMATIC GENERATION CONTROL OF TWO AREA POWER SYSTEM WITH AND WITHOUT SMES: FROM CONVENTIONAL TO MODERN AND INTELLIGENT CONTROL

AUTOMATIC GENERATION CONTROL OF TWO AREA POWER SYSTEM WITH AND WITHOUT SMES: FROM CONVENTIONAL TO MODERN AND INTELLIGENT CONTROL

... the two-area interconnected power system. The two areas are interconnected via a weak link called the tie-line that allows power exchange between ...SMES system can be ... See full document

15

Automatic Generation Control of Three Area Power System with Artificial Intelligent Controllers

Automatic Generation Control of Three Area Power System with Artificial Intelligent Controllers

... common control channel, FHS provides a diversity to be able to find a vacant channel that can be used to transmit and receive the coordination ...primary system, the other hops of FHS can be tried to be ... See full document

16

Automatic Generation Control with Z-N Tuned PID Controller in the Two Area Power System with Energy Storage Unit

Automatic Generation Control with Z-N Tuned PID Controller in the Two Area Power System with Energy Storage Unit

... The Automatic Generation Control is the main control in power system to match the generation with ...demand. Power system size and the type of load, makes ... See full document

8

Load Frequency Control in Two Area Power Systems Integrated with SMES Combination using Fuzzy PID and ANFIS Controller

Load Frequency Control in Two Area Power Systems Integrated with SMES Combination using Fuzzy PID and ANFIS Controller

... generation control scheme in electric power ...and ANFIS controllers are very simple for implementation and gives better dynamic response, but their performance deteriorate when the complexity ... See full document

7

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES MANAGEMENT AUTOMATIC GENERATION CONTROL OF MULTI AREA INTERCONNECTED THERMAL POWER SYSTEM CONSIDERING ASYNCHRONOUS TIE-LINES

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES MANAGEMENT AUTOMATIC GENERATION CONTROL OF MULTI AREA INTERCONNECTED THERMAL POWER SYSTEM CONSIDERING ASYNCHRONOUS TIE-LINES

... on automatic generation control (AGC) problem for a multi-area power system taking into consideration system parameter ...five area power system ... See full document

9

A Novel Hybrid GWO-BFO Approach For Load Frequency Control Problem

A Novel Hybrid GWO-BFO Approach For Load Frequency Control Problem

... Recent control system is a composite ...the control set-up. The idea of controlling the generation automatically is to maintain a balance among the generation and required ...broad ... See full document

9

Automatic Generation Control of Three Area Power Systems Using Ann Controllers

Automatic Generation Control of Three Area Power Systems Using Ann Controllers

... the system dynamic model becomes non-linear and linear control techniques cannot be applied for the optimization of the controller ...the system order will be ... See full document

7

Adaptive Fuzzy Control Approach For Automatic Generation Control Of Two-Area Interconnected Hydro-Thermal System

Adaptive Fuzzy Control Approach For Automatic Generation Control Of Two-Area Interconnected Hydro-Thermal System

... the power system are given in ...in area-1 for all the cases and the deviations in frequency and tie-line power flows were ...-line power flow Ptie under the load disturbances of 0.01 ... See full document

6

Automatic Generation Control of Multi-area Power System using Active Disturbance Rejection Control

Automatic Generation Control of Multi-area Power System using Active Disturbance Rejection Control

... these control loops, proportional- integral-derivative (PID) controllers are normally ...performance, system stability and sustainable utilization of generating systems, PID gains must be well tuned ... See full document

10

Integral Controller for Load Frequency Control in Deregulated Environment

Integral Controller for Load Frequency Control in Deregulated Environment

... the Automatic Generation Control of the two area therma-thermal system in the restructured power system ...the automatic generation control is ... See full document

10

A MATLAB Simulation Study of Automatic Generation Control of Three Area Power System

A MATLAB Simulation Study of Automatic Generation Control of Three Area Power System

... an optimization tool, provides a population-based search procedure in which individuals called particles change their position (states) with ...PSO system, particles fly around in a multi-dimensional search ... See full document

5

ABSTRACT: In this paper, automatic generation control (AGC) of two area interconnected power system having

ABSTRACT: In this paper, automatic generation control (AGC) of two area interconnected power system having

... a two-area power system to investigate the impact of the proposed intelligently controlled AGC including FPID logic with SSC and EDS units on the power system dynamic ...same ... See full document

10

Particle Swarm Optimization Based Automatic Generation Control of Two Area Interconnected Power System

Particle Swarm Optimization Based Automatic Generation Control of Two Area Interconnected Power System

... particle keeps track of its coordinates in the solution region which are associated with the best fitness it has achieved so far. This value is known as „pbest‟. Another „best‟ value that is tracked by the particle is ... See full document

8

Show all 10000 documents...